English
Language : 

TFS120C Datasheet, PDF (1/3 Pages) Vectron International, Inc – Filter specification
tfs 120C.doc
VI TELEFILTER
Filter specification
Version 1.0
TFS 120 C
06.01.02
1/4
1. Measurement condition
Package, pin connection and 50 Ω matching network
Ambient temperature TA:
Input power level:
23 °C
0 dBm
Typical terminating impedances in fN: for input: 1270 Ω  -11,7 pF.
for output: 4330 Ω  -2,9 pF.
(see sheet 2.)
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 120C is the minimum of the pass band attenuation amin. The minimum of the
pass band attenuation amin is defined as the insertion loss ae. The nominal frequence fN is fixed at 120,0 MHz without tolerance or limit.
The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 40 dB filter attenuation level relative to the
insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the
filter in the operating temperature range.
Data
Insertion loss (Reference level) ae
Nominal frequency
fN
Centre frequency fc at ambient temperature ( fCAT )
Pass band
Amplitude ripple (p-p): fN ... fN ± 4,45 MHz
Amplitude ripple (p-p): fN ... fN ± 4,50 MHz
Bandwidth at ambient temperature :
1,0 dB - band width
1,5 dB - band width
3 dB - band width
40 dB - band width
Relative attenuation arel
fN
fN ± 5
MHz
fN - 120
MHz
fN + 25
MHz
Group delay
fN ± 4,5
fN ± 25
fN - 25
fN + 300
MHz
MHz
MHz
MHz
Group delay ripple in pass band (p-p):
Triple transit attenuation compared to main signal
Crosstalk
Frequency inversion temperature ( To )
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature T : *)
Operating temperature range
Storage temperature range
Input power level
Permissible DC voltage
Permissible DC voltage
VDC
Vpp
typ. value
27 ± 0,5 dB
-
120,01 MHz
0,6 dB
-
tolerance / limit
max 33 dB
120,0 MHz
-
fN - 4,5 MHz ... fN + 4,5...MHz
max 3,0 dB
8,98 MHz
9,07 MHz
9,15 MHz
9,90 MHz
-
42...70 dB
70 dB
70 dB
max 3 dB
min 40 dB
3,03 µs
max 6 µs
120 ns
max 400 ns
60 dB
55...67 dB
-5 °C
-0,036 ppm/K²
-
∆fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo(MHz)
-20 °C ... + 75 °C
- 40 °C ... + 85 °C
-
max. + 10 dBm
12 V
10 V
*) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Checked/Approved:
Wadim P. Dunzow
Dr. Bert Wall
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information