English
Language : 

TFS119B Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 119b.doc
VI TELEFILTER
Version 1.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25
°C
0
dBm
1270 Ω || -9,6 pF
1360 Ω || -9,9 pF
TFS 119B
13.12.2006
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 119,6 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 119B is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 9
dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency
Passband
Pass band ripple
p-p
Relative attenuation
f
… f ± 75
N
N
fN ± 400
kHz … fN ± 600
fN ± 600
kHz … fN ± 800
f ± 800
kHz … f ±
3
N
N
f±
3
MHz … f ± 20
N
N
fN - 118,6 MHz … fN -
20
fN + 20
MHz … fN + 500
Group delay ripple within PB
Return loss at fN
Input power level
Operating temperature range
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
ae = amin
fN
fC
PB
arel
kHz
kHz
kHz
MHz
MHz
MHz
MHz
OTR
TCf **
typ. value
6,4 dB
-
119,6
-
0
MHz
dB
0,3 dB
16
dB
28
dB
28
dB
35
dB
75
dB
75
dB
130
ns
25
dB
-
-
-
30
-0,036
°C
ppm/K2
tolerance / limit
max.
8 dB
119,6
-
f ± 75
N
max.
1
MHz
kHz
dB
max.
min.
min.
min.
min.
min.
min.
1 dB
9 dB
20 dB
26 dB
30 dB
55 dB
55 dB
max. 400 ns
min.
9 dB
max.
10 dBm
- 10 °C ... + 85°C
- 45 °C ... + 85°C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.