English
Language : 

TFS1188 Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 1188.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 2.0
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 1188
26.07.2009
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1188,8 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
ae
Nominal frequency
fN
Passband
PB
Pass band variation
Absolute attenuation
700
1100
1220
1260
MHz ...
MHz ...
MHz ...
MHz ...
Group delay at fN
Group delay ripple within PB
1100
1147
1260
1800
VSWR within PB
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
aabs
MHz
MHz
MHz
MHz
OTR
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
typ. value
2,0 dB
-
-
1,0 dB
30
dB
27
dB
8
dB
35
dB
15
ns
25
ns
2,2 : 1
-
-
-
-36
ppm/K
tolerance / limit
max.
2,5 dB
1188,8 MHz
fN
fN
max.
- 14,8
+ 17,2
1,5
MHz
MHz
dB
min.
min.
min.
min.
max.
27 dB
15 dB
2 dB
29 dB
30 ns
max.
40 ns
max.
2,5 : 1
max.
10 dBm
- 45 °C ... + 85 °C
- 45 °C ... + 85 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.