English
Language : 

TFS1176 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 1176.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Filter specification
22
°C
0
dBm
50
Ω
50
Ω
TFS 1176
11.05.2005
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1176,5 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Pass band ripple
Absolute attenuation
1164
MHz
…
1189
850
MHz
…
950
950
MHz
…
1110
1240
MHz
…
1525
1525
MHz
…
1613
1850
MHz
…
2200
Return loss within PB
Group delay ripple within PB
Input power level
Permissible DC voltage
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
**) at ambient temperature
ae
fN
aabs
MHz
MHz
MHz
MHz
MHz
MHz
**
OTR
TCf *
typ. value
2,5 dB
-
-
0,8 dB
2,5
38
36
46
38
32
14
6
-
-
-
-
- 73
dB
dB
dB
dB
dB
dB
dB
ns
ppm/K
tolerance / limit
3 dB
1176,5 MHz
fN
±
max.
12,5 MHz
1,5 dB
max.
3
min.
30
min.
25
min.
25
min.
30
min.
25
min.
9
max.
15
max.
10
max.
0
- 40 °C ... + 85
- 40 °C ... + 85
-
dB
dB
dB
dB
dB
dB
dB
ns
dBm
V
°C
°C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is