Filename: tfs1150A.doc
VI TELEFILTER
Version 1.4
Development specification
TFS1150 A
06.01.2004
1/5
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
100
Output:
100
Characteristics
Remark:
The Reference level for the relative attenuation arel of the TFS1150A is the minimum attenuation in the pass band. The minimum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1150 MHz without tolerance or limit. The values of relative attenuation arel are
guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
Insertion loss
typ. value
ae
-
tolerance / limit
max.
2,7 dB
Nominal frequency
Passband
Relative attenuation
fN -
fN -
5
MHz ... fN +
5
8
MHz ... fN +
8
Absolute attenuation
0
1100
1120
1170
1180
1190
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
MHz ...
1100
1120
1130
1180
1190
1900
Group delay
Group delay ripple within PB
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
**) fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
fN
arel
MHz
MHz
aabs
MHz
MHz
MHz
MHz
MHz
MHz
(0...+ 80°C)
at fN
OTR
TCf **
-
-
-
-
-
-
-
-
-
-
-
-
-
-
T.B.D
ppm/K
fN ±
1150
5
MHz
MHz
max.
max.
1
dB
3
dB
min.
50
dB
min.
35
dB
min.
15
dB
min.
15
dB
min.
35
dB
min.
50
dB
100
ns
35
ns
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D-14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.