English
Language : 

TFS110V Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
tfs110V.doc
VI TELEFILTER
version1.1
19.10.2000
Filter specification
TFS 110V - 1/5
1. Measurement condition :
Ambient temperature :
Input power level :
Terminating impedances :
Q- value :
50...70.
23° C
0 dBm
for input:
for output:
8T9. 0B.ΩM||. -||5T,6. BpF. M.
6T8. 0B.ΩM||. -||5T,9. BpF. M.
2. Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS 110V is the minimum of the pass band attenuation amin. The minimum of the
pass band attenuation amin is defined as the insertion loss ae. The centre (reference) frequency fc is the arithmetic mean value of the upper and
lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
Data
typ. value
Insertion loss (Reference level) ae
11,9 dB
Centre frequency
Pass band shape
fc at ambient temperature TA (fCAT)
(3 dB-BW)
110,592 MHz
Bandwidth at ambient temperature TA :
3 dB bandwidth
10 dB bandwidth
20 dB bandwidth
30 dB bandwidth
40 dB bandwidth
965 kHz
1700 kHz
2320 kHz
2670 kHz
2900 kHz
Relative attenuation arel
fc ....... fc ± 450 kHz
fc ± 450 kHz … fc ± 800 kHz
fc ± 1210 kHz … fc ± 1395 kHz
fc ± 1395 kHz … fc ± 1535 kHz
fc - 10 MHz … fc - 4,5 MHz
fc + 4,5 MHz … fc + 10 MHz
fc ± 10 MHz … fc ± 50 MHz
Average group delay in fc ....fc ± 800 kHz :
Group delay ripple (p-p) in fc ....fc ± 800 kHz :
Deviation from linear phase (p-p) in fc ....fc ± 800 kHz :
Frequency inversion temperature ( To )
Temperature coefficient ( Tc1f ) 1st order (-10 °C ... + 60 °C) *)
Temperature coefficient ( Tc2f ) 2nd order (-10 °C ... + 60 °C) **)
-
45...55 dB
<
32...33 dB
<
50...70 dB
<
1,2 µs
160 ns
3°
20 °C
1,7 ppm/K
- 0,06 ppm/K²
Operating temperature range
Storage temperature range
Input power level
-
Permissible DC voltage VDC
-
Permissible AC voltage Vpp
-
*)
∆fc(Hz) = Tc1f(ppm/K) x (T - To) x fTo (MHz)
** )
∆fc(Hz) = Tc2f(ppm/K) x (T - To)² x fTo (MHz)
fTo is reference frequency fc at frequency inversion temperature (To )
tolerance / limit
max. 13 dB
110,592 ± 0,060 MHz
Gaussian
min. 900 kHz
min. 1600 kHz
max.2420 kHz
max.2700 kHz
max.3070 kHz
max.
max.
min.
min.
min.
min.
min.
3 dB
10 dB
20 dB
30 dB
40 dB
27 dB
40 dB
max. 300 ns
-
- 10 °C ... + 60°C
- 40 °C ... + 85 °C
max. + 10 dBm
12
V
10
V
Generated:
Checked/Approved:
Dunzow W.
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as
a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.