English
Language : 

TFS1000 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 1000.doc
Vectron International
Version 2.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
50 Ω
50 Ω
TFS 1000
12.06.2014
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 1000 MHz. The insertion loss ae is defined as loss value determined at fN. All specified data are met within the
operating temperature range.
Data
Insertion loss
Nominal frequency
Centre frequency
Bandwidth
3 dB
Absolute attenuation
@ 125
@ 250
@ 375
@ 500
@ 625
@ 750
@ 875
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*)
∆f(Hz)
=
TCf(ppm/K)
x
(T
-TB0
)
B
x
fTo(MHz).
ae
fN
fC
BW
aabs
OTR
TCf *
typ. value
2.3
-
1000
dB
MHz
35.29 MHz
80
dB
70
dB
61
dB
56
dB
52
dB
49
dB
46
dB
-
-
-46
ppm/K
tolerance / limit
max.
5.0
1000
-
dB
MHz
-
min.
50 dB
min.
50 dB
min.
50 dB
min.
50 dB
min.
40 dB
min.
40 dB
min.
40 dB
-40 °C ... + 90 °C
-45 °C ... + 95 °C
-
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.