English
Language : 

TFR586 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Resonator specification
Filename: tfr 586.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 2.0
Resonator specification
25
°C
0
dBm
50
Ω
50
Ω
TFR 586
21.03.2005
1/5
Characteristics
Remark:
The minimum of the attenuation amin is defined as the insertion loss ae. The centre frequency fc is the measured frequency at 3 dB. The frequency shift of
the filter in the operating temperature range is not included in the production tolerance scheme.
Data
typ. value
Insertion loss
ae
Center frequency
fC
(center frequency between 3dB points)
Phase at fC
Unloaded quality factor
QU
6,2 dB
586,0375 MHz
153
°
7700
Ageing of fC
Spurious responses
**
-
7
dB
Equivalent circuit elements
Motional capacitance
C1
0,3 fF
Motional inductance
L1
245
nH
Motional resistance
R1
90
Ω
Input / output capacitance
C0
2,2 pF
Input power level
** ***
-
DC breakdown voltage
-
Operating temperature range
OTR
-
Operable temperature range
-
Storage temperature range
-
Frequency inversion temperature
Temperature coefficient of frequency
T0
TCf *
26
°C
- 0,036 ppm/K²
*) ∆f(Hz) = TCf(ppm/K) x (T-T0)² x fTo(MHz).
**) at +65 °C case temperature or less
***) one I/O port is connected to the RF power source (at fC) and the other I/O port is shorted to ground
tolerance / limit
max.
11,5 dB
± 99,5 kHz
max.
-
-
-30/+10 ppm/yr
-
-
-
max. 276
± 0,3
max.
10
min.
30
+ 23 °C ... + 27
- 40 °C ... + 85
- 40 °C ... + 85
± 15
-
Ω
pF
dBm
V
°C
°C
°C
°C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.