English
Language : 

TFR125 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Resonator Specification
Filename: tfr 125.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Resonator Specification
25
°C
0
dBm
50 Ω || 0 pF
50 Ω || 0 pF
TFR 125
28.06.2005
1/5
Characteristics
Remark:
The minimum of the attenuation amin is defined as the insertion loss ae. The centre frequency fc is the measured frequency at the minimum insertion loss
point. The frequency shift of the resonator in the operating temperature range is not included in the production tolerance scheme.
Data
Insertion loss
(reference level)
ae = amin
Resonant frequency at ambient temperature
fC
Quality factor
Q
Unloaded
Parallel capacitance *
C0
Motional resistance *
Rm
Motional inductance *
Lm
Motional capacitance *
Cm
Operating temperature range
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
*) The equivalent circuit model is for reference only.
**) ∆fc(Hz) = Tcf(ppm/K2) x (T – T0) 2 x fCAT (MHz)
OTR
T0
TCf **
typ. value
2,4 dB
-
13600
5,4 pF
34
Ω
620
µH
2,6 fF
-
-
13
-0,038
°C
ppm/K2
tolerance / limit
max.
3,0 dB
125
± 0,05 MHz
min.
8000
-
-
-
-
-20 °C ... + 70°C
-30 °C ... + 150°C
-
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.