English
Language : 

TFH44C Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter Specification
TFH44C.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
25 °C
Input power level:
10 dBm
Terminating impedances
for input: 50 Ω || 0 pF
for output: 50 Ω || 0 pF
Filter Specification
version 1.2
13.03.01
TFH 44 C 1/5
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFH 44C is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the frequency response
of the filter on the operating temperature.
Data
Insertion loss
ae
(Reference level)
Nominal frequency
fN
Centre frequency
fC
Passband
PB
Passband variation
p-p
3 dB bandwidth
BW
Relative attenuation
arel
fN ± 4,00 MHz
fN ± 4,80 MHz ......... fN ± 15 MHz
Group delay variation in PB
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature T:
typ. value
22,6 dB
-
44,0 MHz
0,45 dB
8,11 MHz
tolerance/limit
max. 24,0 dB
44,0 MHz
-
fN ± 2,8 MHz
0,60 dB
min. 8,00 MHz
42
dB
max. 3
dB
min. 40
dB
55
ns
max. 70
ns
-75
ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Operating temperature
Storage temperature range
25
°C
- 25..... + 85
°C
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.