LC120-0-3-0-03 Datasheet, PDF (1/1 Pages) Vectron International, Inc – Nominal centre frequency fo: 120.0 MHz
Specification for LC band pass filter:
1. General
1.1. Package:
LC 120.0-3.0/03
30 August 2012
1.2. Type name:
1.3. Number of poles:
1.4. Operating temperature range ( OTR ):
1.5. Storage temperature range:
LC 120.0-3.0/03
3
-20°C to +70°C
-45°C to +85°C
2. Electric values
2.1. Nominal centre frequency fo:
2.1.1. Center frequency shift in OTR :
120.0 MHz
13 kHz / °C typical
2.2. Pass band
2.2.1. Centre frequency fc at +25°C:
2.2.2. Bandwidth at 3 dB:
2.2.3. Ripple in pass band:
2.2.4. Insertion loss:
typical at -20°C / +25°C / +70 °C:
2.2.5. Return loss at fo:
120.0 MHz ± 300 kHz
< 4.0 MHz and > 3.0 MHz
Gaussian ( no ripple peak to peak )
< 10.0 dB ( in OTR )
6.5dB / 7.5dB / 8.5dB
> 12 dB
2.3. Stop band
2.3.1. Bandwidth at 10 dB:
2.3.2. Bandwidth at 60 dB:
2.3.3. Bandwidth at 80 dB:
2.3.4. Alternate attenuation:
< 6.5 MHz and > 5.5 MHz
< 50 MHz
< 105 MHz
> 60 dB in the range 145….800 MHz
2.4. Terminating impedance ( input and output ):
2.5. Maximum input power level:
50 // 0 pF
+20 dBm
3. Marking:
OEM marking on demand
see marking instruction
4. Environment conditions:
Corresponding to Vectron standard CF001
______________________________________________________________________________________