English
Language : 

C4600_06 Datasheet, PDF (1/4 Pages) Vectron International, Inc – Electronic Frequency Control Input (EFC)
C4600
OCXO
Typical Applications
Base Stations
Digital Switching
Synthesizers
Test Equipment
Previous Vectron Model Numbers
Frequency range
Standard frequencies
Features
Standard Package
Low Aging
AT-Cut and SC-Cut Crystal Options
Fast Warm-up
OCO100, 4598, MC2001 Series
5 MHz – 40 MHz
10; 16.384 MHz
Frequency stabilities1 [AT Cut Crystal – Standard]
Parameter
Min
Typ
Max.
vs. operating temperature range
-30
(Referenced to +25°C)
-80
-100
-200
+30
+80
+100
+200
Parameter
Min
Typ
Max.
Initial tolerance
-300
+300
vs. supply voltage change
-5
+5
vs. load change
-5
+5
vs. aging /1 day
-2.0
vs aging /1 Year
-500
vs. aging / year (following Years)
-250
+2.0
+500
+250
Warm-up Time
3
Frequency stabilities1 [SC Cut Crystal – Option]
Parameter
Min
Typ
Max.
vs. operating temperature range
-10
+10
(Referenced to +25°C)
-15
+15
-20
+20
-30
+30
Parameter
Min
Typ
Max.
Initial tolerance
-100
vs. supply voltage change
-5.0
vs. load change
-5.0
+100
+5.0
+5.0
vs. aging /1 day
-1.0
+1.0
vs aging /1 Year
-100
vs. aging / year (following Years)
-50
+100
+50
Warm-up Time
3
Units
ppb
ppb
ppb
ppb
Units
ppb
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
0 … +70°C
C308
-20 … +70°C
D808
-40 … +70°C
E107
-40 … +85°C
F207
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
to ± 100ppb of final frequency (1 hour reading) @
+25°C
Units
ppb
ppb
ppb
ppb
Units
ppb
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
0 … +70°C
C108
-20 … +70°C
D158
-40 … +70°C
E208
-40 … +85°C
F308
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
to ± 10ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Supply voltage [Option]
Supply voltage [Option]
Power consumption
Min
4.75
11.4
3.135
Typ
5
12.0
3.3
Max.
5.25
12.6
3.465
3.5
1.2
Units
VDC
VDC
VDC
W atts
W atts
Condition
Ordering Code
SV050
SV120
SV033
during warm-up
steady state @ +25°C
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2006-11-10 · page 1 of 4
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax