English
Language : 

C4530 Datasheet, PDF (1/6 Pages) Vectron International, Inc – OCXO Surface Mount Package Reflow Process Compatible AT-Cut and SC-Cut Crystal Options Low Profile Compact Package
C4530
OCXO
Typical Applications
Base Stations
Test Equipment
Synthesizers
Digital Switching
Previous Vectron Model Numbers
Frequency range
Standard frequencies
Features
Surface Mount Package
Reflow Process Compatible
AT-Cut and SC-Cut Crystal Options
Low Profile Compact Package
OCO1000, C4500
10 MHz – 160 MHz
10; 12.8; 16.384; 19.2 ; 20; 26, 30.72, 38.4, 52 MHz
Frequency stabilities1 [AT Cut Crystal – 10 MHz to 160MHz]
Parameter
Min
Typ
Max.
Units
vs. operating temperature range
-100
+100
ppb
(Referenced to +25°C)
-250
+250
ppb
-250
+250
ppb
Parameter
Min
Typ
Max.
Units
Initial tolerance
-500
+500
ppb
vs. supply voltage change
vs. load change
vs. aging / day
vs aging / year
vs. aging / year
-20
-10
-10
-300
-500
+20
ppb
+10
ppb
+10
ppb
+300
ppb
+500
ppb
Warm-up Time
3
minutes
Operating temp range
Ordering Code
-20 … +70°C
D107
-20 … +70°C
D257
-40 … +85°C
F257
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 30 days of operation
≤ 60MHz; after 30 days of operation
>60MHz; after 30 days of operation
to ± 100ppb of final frequency (1 hour reading)
@ +25°C
Frequency stabilities1 [SC Cut Crystal – 15 to 40 MHz]
Parameter
Min
Typ
Max.
vs. operating temperature range
-25
+25
(Referenced to +25°C)
-50
+50
Units
ppb
ppb
Operating temp range
-20 … +70°C
-40 … +85°C
Ordering Code
D258
F508
Parameter
Min
Typ
Max.
Units
Condition
Initial tolerance
-200
+200
ppb
at time of shipment, nominal EFC
vs. supply voltage change
-5.0
vs. load change
-5.0
+5.0
ppb
+5.0
ppb
VS ± 5%
Load ± 5%
vs. aging / day
-1.0
+1.0
ppb
after 30 days of operation
vs aging /1 Year
-100
+100
ppb
after 30 days of operation
vs. aging / year (following Years)
-80
+80
ppb
Warm-up Time
3
minutes to ± 10ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Supply voltage [Option]
Power consumption
Min
Typ
Max.
Units
4.75
5
5.25
VDC
3.135
3.3
3.465
VDC
2.5
Watts
1.0
Watts
Condition
Ordering Code
SV050
SV033
during warm-up
steady state @ +25°C
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2006-02-24 · page 1 of 6
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju
Road, WaiGaoQiao Free Trade Zone,
Pudong, Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax