English
Language : 

C4400_06 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Surface Mount Package Optional
C4400
OCXO
Typical Applications
Base Stations
Test Equipment
Synthesizers
Digital Switching
Previous Vectron Model Numbers
Frequency range
Standard frequencies
Features
4-Pin Dip
Surface Mount Package Optional
Fast Warm-up
TCXO Replacement for better short term
stability
4887, TQDILOC, OC-400
10 MHz – 160 MHz
10; 12, 12.8, 16.384, 19.44, 20, 38.88, 51.84, 133Mhz
Frequency stabilities1 [AT-Cut Crystal – Standard – 10 to 160MHz]
Parameter
M in
Typ
Max.
Units Operating temp range
Ordering Code
vs. operating temperature range
(Referenced to +25°C)
-100
-250
-250
+100
ppb
+250
ppb
+250
ppb
-20 … +70°C
-20 … +70°C
-40… +85°C
D107
D257
F257
Parameter
M in
Typ
Max.
Units
Condition
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / day
vs aging / year
vs. aging / year
-0.5
-10
-10
-10
-300
-500
+0.5
+10
+10
+10
+300
+500
ppm
at time of shipment, nominal EFC
ppb
VS ± 5%
ppb
Load ± 5%
ppb
after 30 days of operation
ppb
≤ 60MHz; after 30 days of operation
ppb
>60MHz; after 30 days of operation
Warm-up Time
2
minutes to ± 100ppb of final frequency (1 hour reading) @
+25°C
Frequency stabilities1 [SC Cut Crystal – Option – 10 to 52MHz]
Parameter
vs. operating temperature range
(Referenced to +25°C)
M in
Typ
Max.
Units
-10
+10
ppb
-25
+25
ppb
-50
+50
ppb
Parameter
M in
Typ
Max.
Units
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging / day
vs aging / year
vs. aging / year
Warm-up Time
-0.2
-10
-10
-5
-100
-500
+0.2
+10
+10
+5
+100
+500
2
ppm
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
-20 … +70°C
D108
-20 … +70°C
D258
-40… +85°C
F508
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 30 days of operation
≤ 60MHz; after 30 days of operation
>60MHz; after 30 days of operation
to ± 100ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Supply voltage [Option]
Supply voltage [Option]
Power consumption
M in
Typ
Max.
Units
4.75
5
5.25
VDC
11.4
12.0
12.6
VDC
3.135
3.3
3.465
VDC
2.5
W atts
1.0
W atts
Condition
Ordering Code
SV050
SV120
SV033
during warm-up
steady state @ +25°C
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germ any
+49-07268-801-0 tel
+49-07268-801-281 fax
v.2006-11-10 · page 1 of 5
Vectron Asia Pacific Sales Office
1F-2F, No 8 Workshop, No 308 Fenju
Road, WaiGaoQiao Free Trade Zone,
Pudong, Shanghai, P.R. China 200131
+86 21 5048 0777 tel.
+86 21 5048 1881 fax