English
Language : 

C2260A1-0015_08 Datasheet, PDF (1/4 Pages) Vectron International, Inc – Nominal frequency (f0)
VECTRON
INTERNATIONAL
C2260A1-0015
TCXO
Nominal frequency (f0)
20 MHz
Frequency stabilities
Parameter
Over all (df/f0)
vs. operating temp. range (df/f@25 °C)
Parameter
initial tolerance (df/f0)
vs. supply voltage change (df/f)
vs. load change (df/f)
vs. aging / 20 years (df/f)
Holdover 24 h
over all: <+/-20ppm for all causes @20years aging
Frequency stability
-20 to 20 ppm
-3.5 to 3.5 ppm
Value
-1 to 1 ppm
-0.3 to 0.3 ppm
-0.2 to 0.2 ppm
<± 10 ppm
± 4.6 ppm
Operating temp. range
-40 ... 85 °C
Condition
@25 °C
static; 3.3 V ±5 %
static; Load ± 10 %
@ 40 °C
24 hrs drift: <+/-0.5ppm
RF output
Parameter
Signal
Load
Rise Time
Fall Time
Duty cycle
V Low
V High
Sub Harmonics
Spurious
Value
LVCMOS
15 pF ±10 %
< 9 ns
< 9 ns
45 / 55 %
x < 0.33 V
x > 2.97 V
<- 80 dBc
<- 80 dBc
Condition
@ 10 to 90 %Vout
@ 90 to 10 %Vout
@ 1.65 V
Supply voltage
Parameter
Supply voltage (Vs)
Current consumption steady state
Value
3.3 V ± 5 %
< 24 mA
Condition
@ Vsnom & 25 °C
Additional Parameters
Parameter
Value
Phase Noise
< -85 dBc/Hz
< -110 dBc/Hz
< -125 dBc/Hz
< -135 dBc/Hz
< -135 dBc/Hz
Start-up time
< 10 ms
Additional information
Phase noise typ.: -89dBc/Hz@10Hz; -110dBc/Hz@100Hz; -140dBc/Hz@1kHz;
-153dBc/Hz@10kHz and -154dBc/Hz@100kHz
Processing & Packing
handling&processing note
Condition
10 Hz
max
100 Hz
values
1000 Hz
10 kHz
100 kHz
Additional environmental conditions
Tensile strength of leads
DIN IEC 68 T2-21 (Ua 1)
Flexibility of leads
DIN IEC 68 T2-21 (Ub)
Sealing test A
nicht dicht (not hermetically sealed)
Solderability
DIN IEC 68 T2-20 (Ta)
100% RoHS compliant
Solvent resistance
EN 60068-2-45, Test xA
washable device
Vectron International • Product Specifications
Vectron International GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
49-07268-801-0 tel
49-07268-801-281 fax
www.vectron.com
modified 2007-02-15 Index : 10 printed 2008-06-25 • page 1 of 4