English
Language : 

CM1964 Datasheet, PDF (1/1 Pages) Chicago Miniature Lamp,inc – Axial Filament Halogen Lamp
engineered to light up your design
www.vcclite.com
1.800.522.5546
Axial Filament Halogen Lamp
Description and Features
.440 MAX.
1 . 8 8 0 ±. 0 5 0
1.125
MAX.
.535 MAX.
.435 MAX.
1.980 MAX.
.535 MAX.
Ø.396-.415
1.75-1.87
.500 MAX.
.210 MAX.
2.250 MAX.
.375 TYP.
.422 TYP.
1.135 MAX.
.394 TYP.
1.063 NOM.
A
B
C
All dimensions are in inches.
Description:
These Axial Filament Halogen Lamps were primarily designed for aircraft navigation lights although their unique
configurations, rugged construction and exceptionally high light output make them the ideal light source for many
applications.
Part No.
CM1964
CM1967
CM1970*
CM1970X
CM1978X*
CM8-A103
Volts
28.0
28.0
28.0
28.0
10.0
28.0
Watts
150
150
100
100
100
50
Filament
Shape
30° Spot
12° N Spot
38° Flood
12° N Spot
38° Flood
12° N Spot
Nominal MSCP
Laboratory
Life Hours
Configuration
230
1000
A
210
1000
A
150
1000
A
140
1000
A
130
2000
B
60
1000
C
* Lamp has a supported filament.
Materials:
Globe: Quartz Glass
Base: Nickel Plated Brass
Atmosphere: Halogen Gas
Caution:
These halogen cycle lamps may shatter if scratched or damaged. Use these lamps in fixtures designed for their high
operating temperature. Always turn power off when changing these lamps. For satisfactory performance limit the seal and
wire lead temperature to 350°C to avoid deterioration. Maintain a minimum lamp wall temperature of 250°C to assure the
halogen cycle occurs. Remove all grease and fingerprints from these lamps before operation. Never exceed the design
voltage of these lamps.
CML and Chicago Miniature Lamp are registered trademarks of Visual Communications Company, LLC.