English
Language : 

UPS602 Datasheet, PDF (8/12 Pages) Unisonic Technologies – HIGH PERFORMANCE CURRENT MODE POWER SWITCH
UPS602
LINEAR INTEGRATED CIRCUIT
FUNCTIONAL DESCRIPTION(Cont.)
(3) Protection section
UPS602 takes on more protection functions such as OLP, OVP and OTP etc. In case of those failure modes for
continual 7.2µs (blanking time), the driver is shut down. At the same time, IC enters auto-restart, VCC power on and
driver is reset after VCC power on again.
OLP
After soft-start phase end (VSS>5.1V), IC will shutdown driver if over load state occurs (corresponding to
VFB>4.6V) for continual 7.2µs. OLP function will not inactive during soft-start phase. OLP case as followed FIG. 6.
The test circuit as followed FIG.8 for UPS602.
VCC
12.6V
8.1V
VOUT
VCC
16V
12.6V
8.1V
T restar t
t
Driver
t
ON/OFF
VFB
7.2µs Blanking
t
7.2µs Blanking
VFB
t
7.2µs Blanking
7.2µs Blanking
4.6V
4.6V
VSS
5.1V
SS Phase
t
t
VSS
SS Phase
5.1V
3.9V
OVP Phase
t 
t
FIG.6 OLP case
FIG.7 OVP case
OVP
Power supply VCC’s OVP function are enabled only when VSS<3.9 & VFB>4.6V during soft-start phase. During
above condition, driver will be shutdown if over voltage state occurs (VCC>16V) for continual 7.2µs. OVP function will
not inactive after soft-start phase. OLP case as followed FIG.7. The test circuit as followed FIG.9 for UPS602.
OTP
OTP will shut down driver when junction temperature TJ of internal circuits is more than threshold 135°C for
continual 7.2µs.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
8 of 12
QW-R119-005,A