ME7660
„ TESTING CIRCUIT
CMOS IC
„ TYPICAL APPLICATION CIRCUIT
Above figure is the basic application circuit to provide a negative supply from -1.5V ~ -10V while a positive
supply from +1.5V ~ +10V is available. When V+=+5V, the output resistance is about 100Ω; The output voltage is
-4V while the load current is 10mA.
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.