English
Language : 

L1923_11 Datasheet, PDF (4/7 Pages) Unisonic Technologies – 500mA HIGH PSRR LDO REGULATORS
L1923
Preliminary
CMOS IC
„ ABSOLUTE MAXIMUM RATING
PARAMETER
SYMBOL
RATINGS
UNIT
VIN to GND
-0.3~7
V
Output Short-Circuit Duration
Infinite
SET to GND
-0.3~7
V
SHDN to GND
-0.3~7
V
SHDN to IN
-7~0.3
V
OUT to GND
Power Dissipation (TA=25°C)
Junction Temperature
Operating Temperature
Storage Temperature
PD
TJ
TOPR
TSTG
-0.3~(VIN+0.3)
V
520
mW
150
°C
-40~85
°C
-65~160
°C
Notes: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
„ THERMAL DATA
PARAMETER
SYMBOL
RATINGS
UNIT
Junction to Ambient
θJA
„ ELECTRICAL CHARACTERISTICS
240
°C/W
(VIN =+3.6V, VSHDN =VIN, TA =TJ =+25°C, unless otherwise specified.) (Note 1)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP MAX UNIT
Input Voltage (Note 2)
Output Voltage Accuracy
Adjustable Output Voltage
Maximum Output Current
VIN
VOUT
VOUT
Variation from specified VOUT, IOUT=1mA
(Note 3)
2.5
-2
VSET
500
5.5 V
2
%
5.5 V
mA
Current Limit (Note 4)
Short Circuit Current
ILIMIT
Isc
600 800
mA
120
mA
Ground Pin Current
IQ
90 120 µA
Dropout Voltage (Note 5)
Line Regulation
Load Regulation
Ripple Rejection
Output Noise
SHUTDOWN
VDROP
ΔVLNR
ΔVLDR
PSRR
Noise
IOUT=250mA
IOUT=500mA
SET=GND, VIN=V(STD)+0.1V~5.5V,
IOUT=10mA
IOUT= 10mA ~500mA
F=100Hz, 0.45VP-P, IOUT=10mA
F≤100kHz, IOUT =0A
F≤100kHz, IOUT =250mA
F≤100kHz, IOUT =500mA
200
mV
400 500
0.06 0.12 %/V
0.02 0.1 %/mA
65
dB
136
238
µV
(RMS)
253
SHDN Input Threshold
SHDN Input Bias Current
Shutdown Supply Current
SET INPUT
VIH
VIL
ISHDN
IQSHDN
Regulator enabled
Regulator shutdown
VSHDN= VIN
VOUT= 0V
TA= +25°C
TA= +25°C
1.5
0.4
V
0.003 0.1 µA
0.2 1
µA
SET Reference Voltage (Note 3)
SET Input Leakage Current
THERMAL PROTECTION
VSET
ISET
VIN= 2.5V ~ 5.5V, TA= +25°C
IOUT= 1mA
TA= TMIN to TMAX
VSET= 1.3V (Note 3) TA= +25°C
1.225 1.25 1.275
1.25
V
5
30
nA
Thermal Shutdown Temperature TSHDN
145
°C
Thermal Shutdown Hysteresis ΔTSHDN
25
°C
Notes: 1.Limits is 100% production tested at TA= +25°C. Low duty pulse techniques are used during test to maintain
junction temperature as close to ambient as possible.
2.Guaranteed by line regulation test.
3.Adjustable mode only.
4.Not tested. For design purposes, the current limit should be considered 600mA minimum to 800mA
maximum.
5.The dropout voltage is defined as (VIN-VOUT) when VOUT is 100mV below the target value of VOUT.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
4 of 7
QW-R502-440.c