English
Language : 

UH210_15 Datasheet, PDF (3/5 Pages) Unisonic Technologies – 2-PHASE DC MOTOR DRIVE IC
UH210
Preliminary
LINEAR INTEGRATED CIRCUIT
 ABSOLUTE MAXIMUM RATING
PARAMETER
SYMBOL
RATINGS
UNIT
Zener Breakdown Voltage
VZ
35
V
NO/SO Pin Voltage
30
V
VCC Pin Voltage
20
V
Peak Sink Current
Hold Current
Continuous Current
IO
IO
700
mA
450
mA
Power Dissipation
TA=25°C
TA=85°C
PD
PD
850
mW
450
mW
Thermal Resistance
Operational Temperature Range
θJA
TOPR
0.15
-20~+100
°C/W
°C
Storage Temperature Range
Junction Temperature
TSTG
TJ
-65~+150
°C
+150
°C
Lead Temperature (Soldering, 10 sec)
TL
+230
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
 DC ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
TEST CONDITIONS
MIN TYP MAX UNIT
Minimum Operating Voltage
Maximum Operating Voltage
VCC No use pin is open (Fig. 1)
VCC ICC<20mA No use pin is open (Fig. 1)
2.8
V
20.0
V
Quiescent Supply Current
NO/SO Saturation Voltage
ICC No use pin is open VCC: 3.0V~20V (Fig. 1)
VSAT IO=450mA (Fig. 1)
18 20 mA
1.0 V
Note: Fig 1 The IC output state is under N magnetic field.
 NO/SO SATURATION VOLTAGE VS. OUTPUT CURRENT(IO) (VCC=12V, TA=25°C)
PARAMETER
Output Saturation Voltage
SYMBOL
TEST CONDITIONS
IOUT =200mA
IOUT =300mA
VO(SAT)
IOUT =400mA
IOUT =500mA
IOUT =600mA
IOUT =700mA
MIN TYP MAX UNIT
0.30
V
0.47
V
0.66
V
0.88
V
1.09
V
1.31
V
 AC ELECTRICAL CHARACTERISTICS
PARAMETER
Rise Time
Fall Time
SYMBOL
TEST CONDITIONS
tR RL=100Ω(5w), CL=20pF (Fig 1)
tF RL=100Ω(5w), CL=20pF (Fig 1)
 MAGNETIC CHARACTERISTICS (TA= -20 ~100°C)
MIN TYP MAX UNIT
10
uS
300
nS
A grade
PARAMETR
Operate Point
Release Point
Hysteresis
B grade
PARAMETR
Operate Point
Release Point
Hysteresis
SYMBOL
MIN
TYP
MAX
UNIT
BOP
+10
BRP
-65
+65
G
-10
G
BHYS
20
130
G
SYMBOL
MIN
TYP
MAX
UNIT
BOP
+5
BRP
-80
+80
G
-5
G
BHYS
10
160
G
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 5
QW-R109-033.b