 ABSOLUTE MAXIMUM RATINGS (Operating temperature range applies unless otherwise specified)
PARAMETER
SYMBOL
RATINGS
UNIT
Cathode Voltage
VKA
37
V
Cathode Current Range(Continuous)
IKA
-100 ~ +150
mA
Reference Input Current Range
IREF
-0.05 ~ +10
mA
Power Dissipation
PD
800
mW
Operating Junction Temperature
Operating Ambient Temperature
Storage Temperature
TJ
+150
°C
TOPR
-40 ~ +85
°C
TSTG
-65 ~ +150
°C
Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Note: Absolute maximum ratings are stress ratings only and functional device operation is not implied.
 RECOMMENDED OPERATING CONDITIONS
Cathode Voltage
Cathode Current
PARAMETER
SYMBOL
VKA
IKA
MIN TYP MAX UNIT
VREF
36 V
1
100 mA
 ELECTRICAL CHARACTERISTICS (TC= 25°C, unless otherwise specified.)
PARAMETER
SYMBOL
TEST CONDITIONS
Reference Input Voltage
Deviation of reference Input Voltage Over
temperature
VREF
ÎVREF
ÎT
VKA=VREF,IKA=10mA
VKA=VREF,IKA=10mA
0°Câ¤Taâ¤70°C
Ratio of Change in Reference Input
Voltage to the Change in Cathode Voltage
Reference Input Current
Deviation of Reference Input Current Over
Full Temperature Range
ÎVREF
ÎVKA
IREF
ÎIREF
ÎT
IKA=10mA
ÎVKA=10V~VREF
ÎVKA=36V~10V
IKA=10mA, R1=10kâ¦, R2=â
IKA=10mA, R1=10kâ¦, R2=â
Ta =full Temperature
Minimum Cathode Current for Regulation IKA(MIN) VKA=VREF
Off-State Cathode Current
IKA(OFF) VKA=36V, VREF=0
Dynamic Impedance
ZKA
VKA=VREF, IKA=1 to 100mA
fâ¤1.0kHz
MIN TYP MAX UNIT
2.470 2.495 2.520 V
4.5 17 mV
-1.0 -2.7 mV/V
-0.5 -2.0 mV/V
1.5 4 µA
0.4 1.2 µA
0.19 0.5 mA
0.05 1.0 µA
0.15 0.5 â¦
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 5
QW-R103-045.A
|
▷ |