Radiometric Intensity
Bin Limits (mW/sr at 20mA)
Bin
Min.
Max.
K
8.5
10.2
L
10.2
12.3
M
12.3
14.7
N
14.7
17.7
P
17.7
21.2
Q
21.2
25.4
R
25.4
30.5
S
30.5
36.6
T
36.6
43.9
Note: Tolerance for each bin will be ± 15%
MVL-5P4TUOL
Note:
1. Luminous intensity is measured with a light sensor and filter
combination that approximates the CIE eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is
half the axial luminous intensity.
3. Iv classification code is marked on each packing bag.
4. The dominant wavelength, λd is derived from the CIE
chromaticity diagram and represents the single wavelength
which defines the color of the device.
Unity Opto Technology Co., Ltd.