English
Language : 

HER601 Datasheet, PDF (1/2 Pages) Won-Top Electronics – 6.0A HIGH EFFICIENCY RECTIFIER
HER601 THRU HER606
6.0 AMP HIGH EFFICIENCY RECTIFIERS
FEATURES
* Low forward voltage drop
* High current capability
* High reliability
* High surge current capability
* High speed switching
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Lead: Axial leads, solderable per MIL-STD-202,
method 208 guranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any
* Weight: 1.65 grams
VOLTAGE RANGE
50 TO 600 Volts
CURRENT
6.0 Amperes
R-6
.360(9.1)
.340(8.6)
DIA.
1.0(25.4)
MIN.
.360(9.1)
.340(8.6)
.052(1.3)
.048(1.2)
DIA.
1.0(25.4)
MIN.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Ta=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 6.0A
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Ta=100 C
Maximum Reverse Recovery Time (Note 1)
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Range TJ, TSTG
HER601
50
35
50
HER602
100
70
100
HER603
200
140
200
HER604
300
210
300
HER605
400
280
400
HER606 UNITS
600
V
420
V
600
V
6.0
A
300
1.0
1.3
10.0
200
60
100
-55 +150
A
1.85 V
A
A
100 nS
pF
C
NOTES:
1. Reverse Recovery Time test condition: IF=0.5A, IR=1.0A, IRR=0.25A
2. Measured at 1MHz and applied reverse voltage of 4.0V D.C.