English
Language : 

TFS70AU Datasheet, PDF (2/5 Pages) Vectron International, Inc – VI TELEFILTER
Filename: tfs 70au.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 70AU
10.01.2006
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
45
50
55
60
65
70
75
80
85
90
95
frequency in MHz
0
2.16
-1
2.04
-2
1.92
-3
1.8
-4
1.68
-5
1.56
-6
1.44
-7
1.32
-8
1.2
-9
1.08
-10
0.96
65
66
67
68
69
70
71
72
73
74
75
frequency in MHz
Construction and pin connection
(All dimensions in mm)
13,6Max.
TFS 70AU
● T38
1
Date code
1,5 2,54 ±0,15
1234
12
5
11
6
10 9 8 7
0,8
0,1
1
Ground
2
Ground
3
Ground
4
Ground
5
Output
6
Output RF Return
7
Ground
8
Ground
9
Ground
10
Ground
11
Input
12
Input RF Return
Date code:
T
U
V
...
Year + week
2005
2006
2007
50 Ω Test circuit
L1
C1
11
5
12 SAW
6
1, 2, 3, 4, 7, 8, 9, 10
L2
C2
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.