English
Language : 

PRL1201D Datasheet, PDF (1/3 Pages) ULTRA LEVEL TECH CO., LTD. – AC-DC ACTIVE PFC SWITCHING POWER SUPPLY
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
We Supply the Power Customers Need ISO9001
300W ~ 400W AC-DC ACTIVE PFC SWITCHING POWER SUPPLY
PRL1201D DUAL OUTPUT SERIES
FEATURES:
◆ 400W convection cooling with 1U height
◆ Design meets IEC/EN/UL60950-1 Latest Edition
◆ Power Factor Corrected to EN61000-3-2 class D
◆ High Quality & Reliable Component Usage
◆ 5/ 12/ 24V Dual Output Optional Combinations
◆ Full Range AC Input
U Type (U-Chassis only):
5(W) x 8(L )x 1.6(H) inches.
PRODUCT SPECIFICATIONS:
Input Voltage: 90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current: 6A at 90VAC full load.
Inrush Current: 70A peak maximum.(Measuring at 230VAC and full
load cold start.)
Power Factor Correction: Pass EN61000-3-2 class D
Transient Response: Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot: Turn-on & turn-off not exceed 5% over nominal voltage.
Efficiency: 80% minimum (Measuring at 115V and full load)
Turn On Delay: 2 second maximum at 115 VAC.
Hold Up Time: 16 m sec. minimum at 115VAC and 75% of rated
maximum load.
Adjustability: Output user adjustable +/-5% minimum.
Remote On-Off: Designated as RSW on the CN3, requires a low
signal to inhibit output.
Power Supply On: When the Bi-color LED emit green light that
indicates the supply is operating. When any protection is occurred or
RSW is applied a low signal, the Bi-color LED will emit orange light.
Power Good: Designated as PG on CN3. This signal will go high
100-500 Msec after the output reaches the regulation limit. It goes
low at least 1 Msec before loss of regulation and has ability to sink
100mA.
Input Circuit Protection (primary): One T6.3A/250V fuse inserted.
Input Voltage Protection: Power shut down under 80 +/-10Vac, and
recovered over 90 Vac.
Over-Power Protection: 110~140% of the rated output current and
recovers automatically.
Over-Voltage Protection: Latching down will occur when output
voltage exceed 130% max., and recycle AC input to reset.
Over Temp. Protection: Protected at ambient 110 +/- 5 ℃; Auto-
recovery.
Short Circuit Protection: Trip without damage and auto-recovery.
Operating Temperature: 0℃ to +50℃
Switching Frequency: PFC 60K Hz; PWM 27K Hz.
Storage Temperature: -20 to +85 degrees C.
Operating Humidity: 5% to 90% RH, Non-condensing.
Storage Humidity: 5% to 95% RH, Non-condensing.
Vibration: Frequency 5 to 50 Hz, acceleration +/-7.35 M/(SxS) on
X,Y and Z Axis.
EMC: EN55022 class B conducted / radiated, EN61000-3-2,
EN61000-3-3; EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-
4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-11).
Safety: Approved UL60950-1, CSA C22.2 No. 950-95, EN60950 and
CB certificate available
Leakage Current: < 500uA at 240Vac
HI-POT Test: 1500 VAC between input line and chassis (10mA AC
cut off current); 3000VAC between primary and secondary windings;
Primary to core 1500VAC. All for 3 sec.
Grounding Test: Apply 25 A from ground pin to the earthed
connection point. Maximum allowable resistance is 0.1ohm.
Warranty: 2 years.
MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30℃.
Burn in: 45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight: 1KG
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.