English
Language : 

PRL0602N Datasheet, PDF (1/4 Pages) ULTRA LEVEL TECH CO., LTD. – AC-DC Active PFC SWITCHING POWER SUPPLY
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
We Supply the Power Customers Need ISO9001
220W ~ 400W AC-DC Active PFC SWITCHING POWER SUPPLY
PRL0602N SINGLE OUTPUT SERIES
FEATURES:
◆ Compact 400W with 1U height Power Density: 11.11 watts/cu in
◆ Active Power Factor Corrected to EN61000-3-2 Class D
◆ Built-in Remote On-Off, Power Good, Fan Fail Alarm
◆ Peak Power 700W within 500uS Duty Duration
◆ Variable Fan Speed & Low Acoustical Noise
◆ High Quality & Reliable Component Usage
◆ Output Voltage ranging from 12 ~ 60Vdc
◆ 4 - Mechanical Options
◆ Full Range AC Input
U Type: 6(L) x 4(W) x 1.5(H)”
E Type: 7(L) x 4(W) x 1.6(H)” F Type: 6(L) x 4(W) x 2(H)” C Type: 6(L) x 4(W) x 1.57(H)”
PRODUCT SPECIFICATIONS:
CB
Input Voltage: 90 ~ 264Vac full range, 47 ~ 63Hz.
Input Current: 8A at 90Vac full load.
Inrush Current: Max. 70A@230Vac & 35A@115Vac; both under
cold start conditions.
Power Factor Correction: >0.9 @ Vin: 230Vac full load.
Transient Response: Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot: Turn-on & off overshoot < 5% over nominal voltage.
Efficiency: 75minimum (Measuring at 230V and full load).
Turn On Delay: 1.5 second maximum at 120 Vac.
Hold Up Time: 16mS min. at 75% of full load at 120Vac.
Adjustability: Output user adjustable +/-5% minimum.
Fan Drive: 12VDC/300mA offering to drive an external fan.
Fan Fail (FF) Alarm: Designated as FF on pin 3 of CN1, two types
of logical signal provided, contact manufacturer.
Remote On-Off: Designated as INH on pin4 of CN1, requires a low
signal to inhibit output.
Power Supply On: Green LED designated as LED1 on the PCB.
Power Good: Designated as PG on CN1 and TTL high 100-500mS
after DC regulation. It goes low at least 1mS before loss of regulation.
Input Fusing Protection: One T8A/250V fuse inserted in primary.
Over-Power Protection: 110~140% of I-Max; Auto-recovery.
Short Circuit Protection: Trip without damage and auto-recovery.
Over Voltage Protection: Unit latching down when output exceed
130% and recycle AC input to reset.
Over-Temperature Protection: Unit protected of excessive
operating ambient 110 ℃±5 ℃, and automatic recovery.
Operating Temperature: 0℃ to 70℃ ambient, de-rating at 2.5% per
degree from 50℃ to 70℃.
Warranty: 2 years.
Switching Frequency: 68kHz PFC, 55 kHz PWM
Vibration: 5 ~ 50 Hz, acceleration ±7.35 m/s*s on X,Y and Z Axis.
Storage Temperature: -20℃ to 85℃.
Operating Humidity: 5% to 90% RH, Non-condensing.
Storage Humidity: 5% to 95% RH, Non-condensing.
EMC: EN55022 class B conducted / radiated, EN61000-3-2,
EN61000-3-3; EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-
4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-11).
Safety Regulation: UL1950, CSA C22.2 No. 950-95, EN60950
and CB certificate
Leakage Current: < 3.5mA @ 264Vac.
(optional for 500uA max. at 240Vac / 300uA max. at 120Vac input)
HI-POT Test: 1500 VAC input line to chassis (10mA AC cut off
current); Isolating 3000VAC primary to secondary windings;
Primary to core 1500VAC. All for 3 sec.
Grounding Test: Apply 25 A from ground pin of the three prong
plug to the far most earth. Max allowable resistance 0.1 ohm.
Warranty: 2 years.
MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30 ℃ .
Cooling:
Internal fan is provided.
Enclosure:
U Type: 6(L) x 4(W) x 1.5(H) inches.
C Type: 6(L) x 4(W) x 1.57(H) inches.
E Type: 7(L) x 4(W) x 1.6(H) inches.
F Type: 6(L) x 4(W) x 2(H)inches.
Burn in: 45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight: Maximum weight is 800g.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.