English
Language : 

TS317L Datasheet, PDF (2/6 Pages) Taiwan Semiconductor Company, Ltd – 3-Terminal Adjustable Output Positive Voltage Regulator
Absolute Maximum Rating
Input Voltage
Vin
40
V
Power Dissipation
Pd
Internal Limited
W
Operating Junction Temperature Range
Storage Temperature Range
Lead Temperature (soldering 4 sec.)
TJ
TSTG
TLEAD
-20 ~ +125
oC
-55 ~ +150
oC
+260
oC
Note: “Absolute maximum rating” indicated limits beyond which damage to the device may occur. Operating ratings
indicate conditions for which the device is functional, but do not guarantee specific performance limits.
Electrical Characteristics
(Tj =TLOW to THIGH see [Note 1], Vin-Vout= 5V, Io=40mA; Pmax per [Note 2]; unless otherwise specified.)
CHARACTERISTIC
CONDITION
SYMBOL MIN. TYP. MAX. UNIT
Reference voltage
(Note 4)
Line regulation
(Note 3)
5mA ≤ Io ≤ 100mA
3V ≤ Vi - Vo ≤ 40V
Tj = 25 oC, 3V ≤ Vi -Vo ≤ 40V,
Io=20mA
Vref
1.20
1.25
1.30
V
REGline
--
0.01
0.07 %/V
Load regulation
(Note 3)
Thermal regulation
Tj = 25 oC, 5mA ≤ IO ≤ Imax,
Tj = 25 oC, 10 ms Pulse
REGload
--
--
--
0.1
1.5
%
0.03
0.2 %/W
Adjustment pin current
Iadj
--
50
100
uA
Adjustment pin current
change
Current limit
Temperature stability
Minimum load current
RMS Noise, % of VO
Ripple rejection ratio
Pd ≤ Pmax, 5mA ≤ Io ≤ Imax,
3V ≤ VI - VO ≤ 40V
3V ≤ VI - VO ≤ 13V
VI - VO = 40V
TLOW ≤ Tj ≤ THIGH
VI - VO ≤ 40V
Ta =25 oC, 10HZ ≤ f ≤ 10KHZ
Vout= 10V, f= 120Hz, Cadj= 0
∆Iadj
ILIMIT
TS
Imin
N
--
--
0.2
5.0
uA
--
200
--
mA
--
50
--
--
0.65
--
%
--
3.5
5
mA
--
0.003
--
%
--
65
--
dB
Long-term stability
(Note 5)
Tj = 125 oC, 1000hrs
S
--
0.3
1.0
%
Thermal resistance
Junction to Ambient
CT package 0.4” leads
CS package
Rθja
--
180
--
oC/W
--
165
--
Notes:
1. TLOW = -20 oC, THIGH = + 125 oC
2. Pmax: CS package=0.5W, CT package=0.625W,
3. Load and line regulation are specified at constant junction temperature. Changes in output voltage due to heating
effects must be taken into account separately. Pulse testing with low duty cycle is used.
4. Selected devices with tightened tolerance reference voltage available.
5. Since Long-Term Stability cannot be measured on each device before shipment, this specification is an engineering
estimate of average stability from lot to lot.
TS317L
2-6
2003/12 rev. A