English
Language : 

TS103_14 Datasheet, PDF (1/6 Pages) Taiwan Semiconductor Company, Ltd – Dual Operational Amplifiers And Voltage Reference
SOP-8
Pin assignment:
1. Output A
2. Input A (-)
3. Input A (+) / Vka
4. Gnd
8. Vcc
7. Output B
6. Input B (-)
5. Input B (+)
TS103
Dual Operational Amplifiers And
Voltage Reference
General Description
The TS103 is a monolithic IC specifically designed to control the output current and voltage levels of switch mode
battery chargers and power supplies. The device contains two operational amplifiers and a precision shunt
regulator. Op Amp 1 is designed for voltage control, whose non-inverting input internally connects to the output of
the shunt regulator. Op Amp 2 is for current control with both inputs uncommitted. The IC offers the power
converter designer a control solution that features increased precision with a corresponding reduction in system
complexity and cost.
Features
● Input Offset Voltage: 0.5mV
● Supply Current: 250uA per OP AMP @ 5V
● Unity Gain Bandwidth: 1MHz
● Output Voltage Swing: 0~(Vcc – 1.5) V
● Power Supply Voltage: 3~18V
● Fixed Output Voltage Reference: 2.5V±1%
● Sink Current Capability from 0.2~80mA
Block Diagram
Ordering Information
Part No.
Package
Packing
TS103CS RLG
SOP-8
2.5Kpcs / 13” Reel
TS103ACS RLG SOP-8
2.5Kpcs / 13” Reel
Note: “G” denote for Halogen Free Product
Absolute Maximum Rating
Parameter
Symbol
Value
Unit
Power Supply Voltage (V to GND)
CC
Op Amp 1 and 2 Input Voltage Range (Pins 2,5,6)
V
20
V
CC
V
-0.3 to V +0.3
V
IN
CC
Op Amp 2 Input Differential Voltage (Pins 5,6)
V
20
V
ID
Voltage Reference Cathode Current (Pin 3)
Power Dissipation
Storage Temperature Range
I
K
P
D
T
STG
100
mA
500
mW
-65 to 150
°C
ESD Protection Voltage (Machine Model)
--
≥200
V
Note 1: Stresses greater than those listed under "Absolute Maximum Ratings " may cause permanent damage
to the device. These are stress ratings only, and functional operation of the device at these or any other
conditions beyond those indicated under "Recommended Operating Conditions" is not implied. Exposure to
"Absolute Maximum Ratings " for extended periods may affect device reliability.
Recommended Operating Conditions
Parameter
Min.
Max.
Unit
Supply Voltage
3
18
V
Ambient Temperature
-40
85
°C
1/6
Version: C12