English
Language : 

TUP110 Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 110 WATT POWER ADAPTERS
TRUMPower
DESCRIPTION
The TUP110 series of AC/DC switching power
supplies are for 110 watts of continuous output
power. They are enclosed in a 94V-1 rated
polyphenylene-oxide case with an IEC 320 inlet to
mate with interchangeable cord for world-wide
use. An on/off switch can be added at request. All
models meet CISPR 22 and FCC class B emission
limits, and comply with UL, CSA, IEC and CE
requirements.
110 WATT POWER ADAPTERS
TUP110 SERIES
(LVD+EMC)
F E AT U R E S
‧ Single, dual, triple or quadruple outputs
‧ Optional output connectors
‧ Optional on/off switch
‧ Optional Power Fail Detect (PFD) signal
‧ 100% burn-in
‧ Wide input range 85 to 264 VAC
‧ Input surge current protection
‧ Overvoltage protections
‧ Overcurrent protections
Safety Standard Approvals:
UL 60950-1
CSA C22.2 No. 60950-1
TÜV EN60950-1
INPUT SPECIFICATIONS
Input voltage: 85 to 264 VAC
Input frequency: 47 to 63 Hz
Input current: 3.20A( rms) for 115VAC
1.80A( rms) for 230VAC
Leakage current: 0.40mA max. @ 115VAC, 60Hz
0.80mA max. @ 230VAC, 50Hz
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
0ºC to +70ºC
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +50ºC
linearly to 50% at +70ºC
OUTPUT SPECIFICATIONS
Output voltage/current: See rating chart
Total output power:
110 watts maximum
Ripple and noise:
1% peak to peak maximum
Overvoltage protection: Provided on output #1 only; set
at 112 – 132% of its nominal
output voltage
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04%/ºC
maximum
Transient response:
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within
500µs after a 25% step load
change
PFD signal (optional): TTL logic high for normal
operation and TTL logic low
upon loss of input power. This
signal appears at least 1ms
prior to +5V output dropping
5% below its nominal value.
This signal also provides a
minimum delay of 100ms after
+5V is within regulation.
GENERAL SPECIFICATIONS
Switching frequency: 20K to 250KHz, varies with load and
line
Efficiency:
70% minimum on single output
models with Vo ≥12V, 65% minimum
on the others
Hold-up time:
12 msec minimum at 110VAC
Line regulation:
±0.5% maximum at full load
Inrush current:
15 amps @ 115VAC, or 30 amps
@ 230VAC, at 25ºC cold start
Withstand voltage: 3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
550,000 hours minimum at full load
at 25ºC ambient , calculated per
MIL-HDBK-217F, excluding DC fan
EMC performance (EN55024)
EN55022:
Class B conducted, class B radiated
FCC:
Class B conducted, class B radiated
VCCI:
Class B conducted, class B radiated
EN61000-3-2: Harmonic distortion, class A
EN61000-3-3: Line flicker
EN61000-4-2: ESD, ±8KV air and ±4KV contact
E N 6 1 0 0 0 - 4 - 3 : Radiated immunity, 3V/m
EN61000-4-4: Fast transient/burst, ±1KV
EN61000-4-5: Surge, ±1KV diff, ±2KV com.
E N 6 1 0 0 0 - 4 - 6 : Conducted immunity, 3Vrms
E N 6 1 0 0 0 - 4 - 8 : Magnetic field immunity, 1A/m
E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30% reduction for 500ms and
>95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com