English
Language : 

TRW24 Datasheet, PDF (1/1 Pages) Tumbler Technologies + TRUMPower – 12~24 Watts AC/DC Wall Mount Power Adapters
TRUMPower
TRW24 Series
12~24 Watts AC/DC Wall Mount Power Adapters
FEATURES
• 90~264 VAC Universal Input
• Interchangeable Plugs Available
• Green Power Meets CEC and ErP Standards
ELECTRICAL SPECIFICATIONS
Input Voltage ................................. 90~264 VAC, 47~63Hz
Input Current ................................. 0.7A (rms) max.
Output Power ................................ 12~24W
Output Voltage, 3~27V .................. CEC level V, ErP Step 2
27~50V ................ CEC level IV, ErP Step 1
Voltage Regulation ....................... ±5% max.
Efficiency @ Full Load .................. 72% typ.
Standby Power @ No Load .......... 0.5W max. for CEC level IV,
0.3W max. for CEC level V
Operating Temperature ................ -10°C to +50°C
Derating ........................................ Derate linearly from 100%
load @ 40°C to 75% load
@ 50°C
Storage Temperature .................... -20°C to +85°C
Operating Humidity ....................... 20% to 90% RH
Protections ................................... OVP, OLP, & short-circuit
Withstand Voltage ......................... 3000 VAC from input to output
Standard Output Connector .......... Barrel plug
Standard Output Cable ................. UL2468, 5ft
STANDARDS & COMPLIANCES
Safety Standards ............ IEC60950-1, UL60950-1, EN60950-1
Agency Approvals ........... UL, cUL, CB, CE
EMI Standards ................ EN55022, Class B
CISPR22, Class B
FCC Part 15
EMC Standards .............. EN61000-3-2, EN61000-3-3,
EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-8,
EN61000-4-11, EN55024
Other Standards ............. CEC, ErP, RoHS
MODELS LIST
Product No. Output Voltage
Output Current
Max. Output Power
TRW24-3-X
3~5V
4~2.4A
12W
TRW24-5-X
5~6V
3~2.5A
15W
TRW24-7-X
6~8V
2.5~1.88A
15W
TRW24-9-X
8~11V
2.5~1.82A
20W
TRW24-12-X
11~13V
2.2~1.85A
24W
TRW24-15-X
13~16V
1.85~1.5A
24W
TRW24-18-X
16~21V
1.5~1.15A
24W
TRW24-24-X
21~27V
1.15~0.9A
24W
TRW24-30-X
27~33V
0.9~0.73A
24W
TRW24-36-X
33~40V
0.73~0.6A
24W
TRW24-48-X
40~50V
0.6~0.48A
24W
Note: X = AC plug code. See the below tables and drawings for details.
X Fixed Wall Mount Plug
U
US Plug
A
Australian Plug
E
EU Plug
B
British Plug
X
Interchangable Plug
I Body for Interchangeable Plugs
IU
US Plug
IA
Australian Plug
IE
EU Plug
IB
British Plug
Ordering Information
1. Specify the output voltage and AC plug code when ordering, e.g. TRW24-7.5-U
for 7.5V output model with a fixed US wall plug.
2. For interchangeable plug orders, at least one interchangeable plug must be
ordered together with the "main body" (X = I).
3. Contact TRUMPower for output connector options.
MECHANICAL DRAWINGS
Fixed US Plug
43.5±0.3
Fixed Australian Plug
43.50±0.3
I-Body for Interchangeable Plugs Interchangeable Plugs
43.5±0.3
40.5±0.3
IA
IB
35.7±0.3
Fixed EU Plug
43.50±0.3
35.70±0.3
Fixed British Plug
43.50±0.3
36.5±0.3
IE
IUI/UIC
35.7±0.3
35.70±0.3
Unit: mm
#TRW24-2011-0213
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA • 408-988-6616 • sales@trumpower.com • www.TRUMPower.com