English
Language : 

TOP100-12 Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 60-96 WATT AC/DC SWITCHING POWER SUPPLIES
T P L N - 1 0 0 T10O0WP1Si0n0gleSOeurtpieutsSw6i0tc-h9in6gWPoAwTeTr SAuCpp/lDy C SWITCHING POWER SUPsPeLrIiEeSs
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in active PFC function
IP64 design for indoor or outdoor installations
UL1310 Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
2 years warranty
SPECIFICATION
F
110
M
LPS M SELV
EQUIVALENT
( for 48V only)
IP64 ( except for 48V )
PM/ONDEL
OUTPUT
TPOLNP-110000--1122 TPOLNP-110000--1155 TPOLNP-110000--2200 TPOLNP-110000--2244
DC VOLTAGE
12V
15V
20V
24V
CONSTANT CURRENT REGION Note.7 6 ~ 12V
7.5 ~ 15V
10 ~ 20V
12 ~ 24V
RATED CURRENT
Note.6 5A
5A
4.8A
4A
CURRENT RANGE Note.6 0 ~ 5A
0 ~ 5A
0 ~ 4.8A
0 ~ 4A
RATED POWER
Note.6 60W
75W
96W
96W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
0% ~ -15%. Can be adjusted by internal potential meter SVR1
CURRENT ADJ. RANGE
3% ~ -25%. Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE Note.3 3.0%
3.0%
3.0%
3.0%
LINE REGULATION
1.0%
LOAD REGULATION
2.0%
SETUP, RISE TIME
1200ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load
HOLD UP TIME (Typ.)
60ms/230VAC 30ms/115VAC at full load
TPOLNP-110000--2277
27V
13.5 ~ 27V
3.55A
0 ~ 3.55A
95.85W
150mVp-p
3.0%
TPOLNP-110000--3366
36V
18 ~ 36V
2.65A
0 ~ 2.65A
95.4W
150mVp-p
2.0%
TPOLNP-110000--4488
48V
24 ~ 48V
2A
0 ~ 2A
96W
200mVp-p
2.0%
INPUT
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.95/115VAC at full load
EFFICIENCY (Typ.)
83%
85%
87%
87%
87%
87%
AC CURRENT (Typ.)
12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC 20V ~ 48V:1.1A/115VAC
INRUSH CURRENT (Typ.) COLD START 40A/230VAC
87%
0.55A/230VAC
LEAKAGE CURRENT
0.5mA / 240VAC
OVER CURRENT
95 ~ 100%
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
13 ~ 16V
16.5 ~ 20V
22 ~ 27V
27 ~ 34V
29 ~ 36V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
39 ~ 48V
OVER TEMPERATURE
90 10 (RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
52 ~ 64V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
-30 ~ +50 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
EMC
OTHERS
NOTE
SAFETY STANDARDS
UL1310 Class 2, UL879 ( listed in UL Sign Components Manual (SAM) ), TUV EN60950-1, EN61347-1, EN61347-2-13
CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved
WITHSTAND VOLTAGE
I/P-O/P:4.25KVDC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55015, EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2 Class C (>50% load) ; EN61000-3-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level, criteria A
MTBF
303.1Khrs min. MIL-HDBK-217F (25 )
DIMENSION
200*70.5*35mm (L*W*H)
PACKING
0.52Kg; 20pcs/11.4Kg/0.76CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to OLP characteristics.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
7. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
File Name:PLN-100-SPEC 2008-08-18