English
Language : 

TMP60 Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 30-60 WATT MEDICAL POWER ADAPTERS
TRUMPower 30-60 WATT MEDICAL POWER ADAPTERS
DESCRIPTION
The PMP60 is a series of AC/DC switching power adapters
consists of 30 to 60 watts single, dual and triple outputs.
They are enclosed in a 94V-1 rated polyphenylene-oxide
case with an IEC 320/C14 inlet to mate with interchangeable
cord for world-wide use. All models meet CISPR 11 and
FCC class B emission limits, and are designed for medical
applications where low earth leakage current is required.
TMP60 SERIES
(LVD)
RoHS
FEATURES
‧ Desktop form factor
‧ Single, dual, or triple outputs
‧ Optional output connectors
‧ 100% burn-in
‧ W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C
‧ Input surge current protection
‧ Overvoltage protection
‧ Overcurrent protection
‧ Compliant with CEC and Energy Star Efficiency
level IV requirements
* No load power consumption less than 0.5W
* Average active efficiency ≧ 85%
‧ Compliant with RoHS requirement
Safety Standard Approvals:
UL 60601-1
CSA C22.2 No. 601.1
INPUT SPECIFICATIONS
Input voltage:
8 5 t o 2 6 4 VA C
Input frequency: 47 to 63 Hz
Input current:
1 . 3 0 A ( r m s ) f o r 11 5 VA C
0 . 7 0 A ( r m s ) f o r 2 3 0 VA C
L e a k a g e c u r r e n t : 9 0 u A m a x . @ 11 5 VA C , 6 0 H z
1 5 0 u A m a x . @ 2 3 0 VA C , 5 0 H z
TÜV EN60601-1
GENERAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Output voltage/current: See rating chart
Total output power:
See rating chart
Ripple and noise:
2﹪peak to peak maximum
Overvoltage protection:
Provided on output #1 only; set
at 112-140﹪of its nominal
output voltage
Overcurrent protection:
All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04﹪ /℃
maximum
Transient response:
Maximum excursion of 4﹪or
better on all models, recovering
to 1﹪of final value within
500us after a 25﹪ step load
change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0℃ to +60℃
Storage temperature: -40℃ to+85℃
Relative humidity:
Derating:
5﹪ to 95﹪ non-condensing
Derate from 100﹪ at +40℃
linearly to 50﹪at +60℃
Switching frequency: 40KHz - 130KHz
Efficiency:
Hold-up time:
Line regulation:
85﹪minimum on single output models,
65﹪minimum on the others
10 msec minimum at 110VAC
±0.5﹪ maximum at full load
Inrush current:
50 amps @ 115VAC, or 100 amps
@230VAC, at 25℃ cold start
Withstand voltage: 4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
150,000 hours minimum at full load at
25℃ambient , calculated per
MIL-HDBK-217F
EMC performance (EN60601-1-2)
EN55011:
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion , Class A
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD,± 8KV air and ± 6KV contact
EN61000-4-3:
Radiated immunity, 3V/m for 80~2500MHz
EN61000-4-4:
Fast transient/burst, ± 2KV
EN61000-4-5:
Surge, ± 1KV diff., ± 2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 3A/m
EN61000-4-11:
Voltage dips, 30﹪ reduction for 500ms,
60% reduction for 100ms and >95﹪
reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com