200 Watts AC/DC Medical & ITE Power Supplies
FEATURES
• 90~264 VAC Input with Active PFC
• 3" x 5" x 1.5" Compact Size
• 0.98 Power Factor
• Low Leakage Current
• Efficiency up to 92%
INPUT SPECIFICATIONS
Input Voltage Range .............. 90~264 VAC
Input Frequency ..................... 47~63Hz
Input Current .......................... 2.5A rms @ 115 VAC
1.25A rms @ 230 VAC
Inrush Current ....................... 20A @ 115 VAC or 40A @ 230 VAC,
at 25°C cold start
Earth Leakage Current .......... 220µA max. @ 264 VAC, 63Hz
Touch Current ........................ 100µA max. @ 264 VAC, 63Hz
OUTPUT SPECIFICATIONS
Output Power Ratings ........... See table
Output Voltage ....................... See table
Tolerance ............................... ±2%
Ripple and Noise* ................. 1% peak to peak max.
Overvoltage Protection .......... Set at 112-140% of its nominal
output voltage
Overcurrent Protection .......... Protected to short-circuit
conditions
Temperature Coefficient ....... ±0.04%/°C max.
Transient Response ............. Max. excursion of 4% or better on
all models, recovering to 1% of
final value within 500µs after a
25% step load change
Fan Power ............................. 12V at 250mA max.
* Peak to peak with 20MHz bandwidth and 10µF tantalum capacitor in parallel with a
0.1µF ceramic capacitor at rated line voltage and load ranges
GENERAL SPECIFICATIONS
Switching Frequency ............. 100KHz typical
Power Factor ......................... 0.98 typical, with active PFC
Efficiency ............................... 87% min. on all models
Hold-up Time ......................... 10ms at 110 VAC
Line Regulation ..................... ±0.5% max. at full load
Operating Temperature ........ 0°C to +70°C
Derating ................................. Derate from 100% @ +50°C
linearly to 50% @ +70°C
Storage Temperature ............ -40°C to +85°C
Relative Humidity .................. 5% to 95% non-condensing
Withstand Voltage ................. 4000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
MTBF ...................................... 350K hours minimum at full load,
25°C ambient, calculated per
MIL-HDBK-217F
MODELS LIST
Output
Product No. [1]
Voltage
@ Convection
Max.
Current
Max.
Power [2]
@ 5.3 CFM Forced Air
Max.
Current
Max.
Power [2]
TMC200-S12
12V
TMC200-S15
15V
TMC200-S18
18V
TMC200-S24
24V
TMC200-S28
28V
TMC200-S36
36V
TMC200-S48
48V
12.50A
10.00A
8.34A
6.25A
5.36A
4.17A
3.13A
150W
150W
150W
150W
150W
150W
150W
16.67A
13.34A
11.12A
8.34A
7.15A
5.56A
4.17A
200W
200W
200W
200W
200W
200W
200W
NOTES:
1. U-bracket format is standard. Add suffix “C” for enclosed format with
cooling fan, e.g. TMC200-S12C.
2. 150W without moving air or 200W with 5.3 CFM forced air provided by
user for U-bracket format, 200W for “C” version with cover-and-fan
assembly. The adequacy of cooling air is judged by the measured core
temperature of transformer T1 below 75°C at 25°C ambient, or below
100°C at 50°C ambient.
STANDARDS & COMPLIANCES
EN55011, EN55022 .......... Class B conducted and radiated
FCC .................................... Class B conducted and radiated
VCCI ................................... Class B conducted and radiated
EN61000-3-2 ..................... Harmonic distortion, Class A & D
EN61000-3-3 ..................... Line flicker
EN61000-4-2 ..................... ESD, ±8 KV air and ±6 KV contact
EN61000-4-3 ..................... Radiated immunity, 3V/m
EN61000-4-4 ..................... Fast transient/burst, ±2 KV
EN61000-4-5 ..................... Surge, ±1 KV diff., ±2 KV com.
EN61000-4-6 ..................... Conducted immunity, 3 Vrms
EN61000-4-8 ..................... Magnetic field immunity, 3A/m
EN61000-4-11 ................... Voltage dips immunity,
30% reduction for 500ms,
60% reduction for 100ms,
>95% reduction for 10ms
Safety Standards ............... UL 60601-1, EN 60601-1,
CSA C22.2 No. 601.1,
UL 60950-1, EN 60950-1,
CSA C22.2 No. 60950-1
Agency Approvals .............. UL, cUL, TUV, CB, CE
Other Compliance ............. RoHS
Tumbler Technologies + TRUMPower