TM300 Datasheet, PDF (1/3 Pages) Tumbler Technologies + TRUMPower – 300 WATT MEDICAL POWER SUPPLIES
TRUMPower
300 WATT MEDICAL POWER SUPPLIES
DESCRIPTION
The TM300 series comprising single and multiple
output models for 200 to 300 watts of continuous
output power is specially designed for medical
applications. They operate at 90 to 264VAC input
voltage without the need of a selector strap. All
auxiliary outputs are with magnetic amplifier to
keep regulation. The units are constructed on a
printed circuit board with a U-bracket for
mechanical support and heat sinking. A
cover-and-fan assembly can be added during
manufacturing.
TM300 SERIES
( LV D )
RoHS
F E AT U R E S
‧ EN61000-3-2 class A and D compliant
‧ Power Factor 0.98 typical
‧ Overvoltage protection
‧ Short-circuit protection
‧ Power Fail Detect (PFD)
‧ 100% burn-in at full rated load
‧ Remote sense on output #1 and output #2
‧ Remote inhibit – TTL high disables output
‧ Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltage :
Input frequency:
Input current :
90 to 264VAC
47 to 63Hz
4.7A (rms) for 115VAC
2.3A (rms) for 230VAC
Earth leakage current:
100µA max. @115VAC, 60Hz
220µA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and Noise:
Overvoltage protection:
Overcurrent protection:
Temperature coefficient:
See rating chart
See rating chart
2% peak to peak maximum
Provided on output #1 only; set
at 115–140% of its nominal
output voltage
All outputs protected
to short circuit conditions
All outputs ±0.04%/ºC
maximum
Transient response:
Maximum excursion of 4%
or better on all models,
recovering to 1% of final value
within 500µs after a 25% step
load change
PFD signal:
Remote inhibit:
TTL logic high for normal
operation and TTL logic low
upon loss of input power.
This signal appears at least
1ms prior to master output
dropping 5% below its nominal
value. This signal also
provides a minimum delay of
100ms after master output is
within regulation.
Requires an external TTL
high level signal to inhibit
outputs for standard models.
Safety Standard Approvals:
UL 60601-1
CSA C22.2 No. 601.1
TÜV EN60601-1
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0ºC to +70ºC
Storage temperature: -40ºC to +85ºC
Relative humidity:
5% to 95% non-condensing
Derating:
Derate from 100% at +50ºC
Cooling:
linearly to 50% at +70ºC
200/250/300 watts continuous
output power at 35 CFM forced
air cooling or 100/125/150 watts
at convention cooling
GENERAL SPECIFICATIONS
Switching frequency:
KHz ±10KHz
Power factor:
0.98 typical
Efficiency:
70% minimum on all models
Hold-up time:
12 msec minimum at 110VAC
Line regulation:
Inrush current:
±0.2% maximum at full load
30 amps @ 115VAC or 60 amps
@230VAC, at 25ºC cold start
Withstand voltage:
MTBF:
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
300,000 hours minimum at full load
at 25ºC ambient, calculated per
MIL-HDBK- 217F
EMC Performance (EN60601-1-2: 2001)
EN55011:
Class B conducted, Class B
radiated
EN61000-3-2:
Harmonic distortion, Class A and D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±6KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ±2KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 3A/m
EN61000-4-11:
Voltage dips, 30% reduction for
500ms, 60% reduction for 100ms
and >95% reduction for 10ms
Tumbler Technologies + TRUMPower