TM25 Datasheet, PDF (1/3 Pages) Tumbler Technologies + TRUMPower – 25-28 WATT MEDICAL POWER SUPPLIES | |||
|
TRUMPower 25-28 WATT MEDICAL POWER SUPPLIES
DESCRIPTION
The TM25 series of compact, open PCB constructed,
AC-DC switching power supplies are capable of
delivering 25 to 28 watts of continuous output
power. They operate at 85 to 264VAC input voltage
without the need of voltage selection. They are
ideally suited for use in medical equipments, safety
systems and monitoring equipments.
TM25 SERIES
( LV D )
RoHS
FEATURES
⧠Low safety ground leakage current
⧠100% burn-in
⧠85 to 264VAC wide input range
⧠Input surge current protection
⧠Overvoltage protection
⧠Overcurrent protection
⧠Open PCB construction
⧠Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltageï¼
85 to 264VAC
Input frequencyï¼
47 to 63 Hz
Input currentï¼
0.7Aï¼ rmsï¼ for 115VAC
0.4Aï¼ rmsï¼ for 230VAC
E a r t h l e a k a g e c u r r e n tï¼ 9 0 µ A m a x . @ 11 5 VA C , 6 0 H z
150µA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/currentï¼ See Rating Chart
Total output powerï¼
See Rating Chart
Ripple and noiseï¼
1% peak to peak max.
Overvoltage protectionï¼ Provided on output #1 only;
set at 112-132% of its
nominal output voltage
Overcurrent protectionï¼ All outputs protected to short
circuit conditions
Temperature coefficientï¼ All outputs ±0.04%/ºC
maximum
Transient responseï¼
Maximum excursion of 4%
or better on all models,
recovering to 1% of final
value within 500µs after a
25% step load change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0ºC to +70ºC
Storage temperatureï¼ -40ºC to +85ºC
Relative humidityï¼
5% to 95% non-condensing
Deratingï¼
Derate from 100% at +50ºC
linearly to 50% at +70ºC
Safety Standard Approvalsï¼
UL 2601-1
CSA C22.2 No. 601.1
TÃV EN60601-1
GENERAL SPECIFICATIONS
Switching frequencyï¼ 42KHz ±5KHz
Efficiencyï¼
70% minimum on single output
model with Vo ⥠12V, 68% minimum
on the others
Hold-up timeï¼
10 msec minimum at 110VAC
Line regulationï¼
±0.5% maximum at full load
Inrush currentï¼
10 amps @ 115VAC or 25 amps
@ 230VAC at 25ºC cold start
Withstand voltageï¼
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBFï¼
500,000 hours minimum at full load
at 25ºC ambient, calculated per
MIL- HDBK- 217F
EMC Performance (EN60601-1-2:2001)
EN55011:
FCC:
VCCI:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
EN61000-3-2: Harmonic distortion, Class A and D
EN61000-3-3: Line flicker
EN61000-4-2: ESD, ±8KV air and ±6KV contact
E N 6 1 0 0 0 - 4 - 3 : Radiated immunity, 3V/m for 80~2500 MHz
EN61000-4-4: Fast transient/burst, ±2KV
EN61000-4-5: Surge, ±1KV diff, ±2KV com.
E N 6 1 0 0 0 - 4 - 6 : Conducted immunity, 3Vrms
E N 6 1 0 0 0 - 4 - 8 : Magnetic field immunity, 3A/m
EN61000-4-11:
Voltage dips, 30% reduction for 500ms,
60% reduction for 100ms and >95%
reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 â Fax: 408-988-6622 â email: sales@trumpower.com â Website: www.TRUMPower.com
|
▷ |