TFC130S Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – PFC 130 WATT POWER SUPPLIES | |||
|
TRUMPower
DESCRIPTION
The TFC130 series incorporates creative high
efficiency circuitry, high power density (6.94
Watts/in3) and active Power Factor Correction
(PFC) to meet the requirements of data
networking, computing and telecommunication
systems.
PFC 130 WATT POWER SUPPLIES
TFC130 SERIES
(SINGLE OUTPUT)
(LVD)
RoHS
FEATURES
⧠EN61000-3-2 class A and D compliant
⧠Power factor 0.98 typical
⧠Very compact size, 3â³Ã5â³Ã1.2â³
⧠Overvoltage protections
⧠Short circuit protections
⧠Remote sense
⧠Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltageï¼
90 to 264VAC
Input frequencyï¼
47 to 63Hz
Input currentï¼
2.1Aï¼ rmsï¼ max. for 115VAC
1.1Aï¼ rmsï¼ max. for 230VAC
Earth leakage current: 0.3mA max. @ 115VAC, 60Hz
(Touch current)
0.6mA max. @ 230VAC, 50Hz
Safety Standard Approvalsï¼
UL 60950-1
CSA C22.2 No. 60950-1
TÃV EN60950-1
OUTPUT SPECIFICATIONS
Output voltage/currentï¼ See Rating Chart
Ripple and noiseï¼
2% peak to peak on 5.1V model
1% peak to peak on other
models.
Overvoltage protectionï¼ Provided on output set at
112â132% of its nominal output
voltage
Overcurrent protectionï¼ Protected to short circuit
conditions
Temperature coefficientï¼All outputs ± 0.04%/ºC maximum
Transient responseï¼ Maximum excursion of 4% or
better on all models; recovering
to 1% of final value within 500µs
after a 25% step load change
ENVIRONMENTAL SPECIFICATIONS
Operating temperatureï¼ -10ºC to +60ºC
Storage temperatureï¼ -40ºC to +85ºC
Relative humidityï¼
5% to 95% non-condensing
Deratingï¼
Derate from 100% at +40ºC
linearly to 50% at +60ºC
Coolingï¼
10 CFM total forced air from two
40mm diameter fans or the like
is required and provided by user
GENERAL SPECIFICATIONS
Switching frequencyï¼ 110KHz ±15KHz
Power factorï¼
0.98 typical
Efficiencyï¼
72% typical on 5.1V output,
76% typical on other outputs
Hold-up timeï¼
15 msec minimum at 115VAC
Line regulationï¼
±0.5% maximum at full load
Inrush currentï¼
35 amps @ 115VAC or 70 amps
@ 230VAC at 25ºC cold start
Withstand voltageï¼ 3000VAC from input to output
MTBFï¼
1500VAC from input to ground
500VAC from output to ground
200,000 hours minimum
EMC Performance (EN55024)
EN55022:
Class B conducted, class A radiated
FCC Part 15
VCCI:
Class B conducted, class A radiated
Class B conducted, class A radiated
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
Harmonic distortion, class A and D
Line flicker
ESD, ±8KV air and ±4KV contact
EN61000-4-3:
EN61000-4-4:
Radiated immunity, 3V/m
Fast transient/burst, ±1KV
EN61000-4-5:
EN61000-4-6:
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
EN61000-4-11:
Voltage dips, 30% reduction for 500ms
and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 â Fax: 408-988-6622 â email: sales@trumpower.com â Website: www.TRUMPower.com
|
▷ |