TFC130M Datasheet, PDF (1/3 Pages) Tumbler Technologies + TRUMPower – PFC 130 WATT POWER SUPPLIES | |||
|
TRUMPower
DESCRIPTION
The TFC130 series incorporates creative high
efficiency circuitry, high power density (6.94
Watts/in3) and active Power Factor Correction
(PFC) to meet the requirements of data
networking, computing and telecommunication
systems. Some models with one or two outputs
adjustable between 5V and 24V intend to suit
more applications.
PFC 130 WATT POWER SUPPLIES
TFC130 SERIES
(MULTIPLE OUTPUT)
(LVD)
RoHS
F E AT U R E S
⧠EN61000-3-2 class A and D compliant
⧠Power factor 0.98 typical
⧠Very compact size, 3â³Ã5â³Ã1.2â³
⧠Overvoltage protection
⧠Short circuit protection
⧠Remote sense on 3.3V output
⧠Power Good/Power Fail Detect Signal
⧠Up to five DC outputs
⧠All outputs well regulated
⧠Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltageï¼
90 to 264VAC
Input frequencyï¼
47 to 63Hz
Input currentï¼
2.1Aï¼ rmsï¼max. for 115VAC
1.1Aï¼ rmsï¼max. for 230VAC
Earth leakage current:
(Touch Current)
0.3mA max. @ 115VAC, 60Hz
0.6mA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/currentï¼ See Rating Chart
Ripple and noiseï¼
65mV peak to peak on V1,1%
peak to peak on other outputs
Overvoltage protectionï¼ Provided on V0 & V1; set at
112â132% of its nominal
output voltage
Overcurrent protectionï¼ All outputs protected to short
circuit conditions
Temperature coefficientï¼ All outputs ±0.04/ºC maximum
Transient responseï¼
Maximum excursion of 4%
or better on all models,
recovering to 1% of final
value within 500µs after
a 25% step load change
PG/PFD signalï¼
TTL logic high for normal
operation and TTL logic low
upon loss of input power.
This signal appears at least
10ms prior to master output
dropping 5% below its
nominal value. This signal
also provides a minimum
delay of 100ms after master
output is within regulation
Safety Standard Approvalsï¼
UL 60950 3rd
CSA C22.2 No. 60950 3rd
TÃV EN60950-1
ENVIRONMENTAL SPECIFICATIONS
Operating temperatureï¼ -10ºC to +60ºC
Storage temperatureï¼ -40ºC to +85ºC
Relative humidityï¼
Deratingï¼
5% to 95% non-condensing
Derate from 100% at +40ºC
Coolingï¼
linearly to 50% at +60ºC
10 CFM total forced air
from two 40mm diameter
fans or the like is required
and provided by user.
GENERAL SPECIFICATIONS
Switching frequencyï¼ 100KHz ±10KHz
Power factorï¼
0.98 typical
Efficiencyï¼
75% typical
Hold-up timeï¼
15 msec minimum at 115VAC
Line regulationï¼
±0.5% maximum at full load
Inrush currentï¼
35 amps @ 115VAC or 70 amps
@ 230VAC at 25ºC cold start
Withstand voltageï¼ 3000VAC from input to output
MTBFï¼
1500VAC from input to ground
500VAC from output to ground
200,000 hours minimum
EMC Performance (EN55024)
EN55022:
FCC Part 15
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
Class B conducted, class A radiated
Class B conducted, class A radiated
Class B conducted, class A radiated
Harmonic distortion, class A and D
Line flicker
ESD, ±8KV air and ±4KV contact
Radiated immunity, 3V/m
Fast transient/burst, ±1KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 1A/m
Voltage dips, 30% reduction for
500ms and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 â Fax: 408-988-6622 â email: sales@trumpower.com â Website: www.TRUMPower.com
|
▷ |