PUP60 Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 60-130 WATT DESKTOP POWER ADAPTERS | |||
|
60-130 WATT DESKTOP POWER ADAPTERS
DESCRIPTION
PUP60/80/130 SERIES
(LVD+EMC)
The PUP60/80/130 series of AC/DC switching power supplies
are for 60 to 130 watts of continuous output power. They are
enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC
320 inlet to mate with interchangeable cord for world-wide use.
An on/off switch can be added at request. All models meet
CISPR 22 and FCC class B emission limits, and comply with UL,
CSA, IEC and CE requirements.
FEATURES
⧠Optional output connectors
⧠Optional on/off switch
⧠100﹪ burn-in at full rated load
⧠Auto-ranging input
⧠Input surge current protection
⧠Overvoltage protection
⧠Overcurrent protection
⧠Thermal protection
INPUT SPECIFICATIONS
Input voltageï¼
9 0 t o 1 3 0 VA C o r 1 8 0 t o 2 6 0 VA C
(auto-ranging)
Input frequencyï¼ 47 to 63 Hz
Input currentï¼
P U P 6 0 / 8 0 S e r i e s : 1 . 8 A ï¼ r m s ï¼ f o r 11 5 VA C
1 . 0 A ï¼ r m s ï¼ f o r 2 3 0 VA C
PUP130 Series:
3 . 0 m A ( r m s ) f o r 11 5 VA C
1 . 7 A ï¼ r m s ï¼ f o r 2 3 0 VA C
L e a k a g e c u r r e n t ï¼ 0 . 4 0 m A m a x . @ 11 5 VA C , 6 0 H z
0 . 8 0 m A m a x . @ 2 3 0 VA C , 5 0 H z
OUTPUT SPECIFICATIONS
Output voltage/currentï¼
Output power rangeï¼
Ripple and noiseï¼
Overvoltage protectionï¼
See rating chart
See rating chart
1﹪peak to peak maximum
Provided on output; set at 112 -
132﹪of its nominal output
voltage
Overcurrent protectionï¼
Temperature coefficientï¼
Transient responseï¼
All outputs protected to short
circuit conditions
All outputs ±0.04﹪/â
maximum
Maximum excursion of 4﹪or
better on all models, recovering
to 1﹪of final value within 500us
after a 25﹪step load change
ENVIRONMENTAL SPECIFICATIONS
O p e r a t i n g t e m p e r a t u r e ï¼ 0â to +40â (PUP60/80 series)
0â to +50â (PUP130 series)
Storage temperatureï¼
Relative humidityï¼
-40â to +85â
5﹪ to 95﹪ non-condensing
Safety Standard Approvalsï¼
UL 60950-1
CSA C22.2 No. 60950-1
TÃV EN60950-1
GENERAL SPECIFICATIONS
Switching frequencyï¼ 60KHz to 75KHz
Efficiencyï¼
70 ﹪ minimum on Vo ⧠12V ,
65% minimum on the others
Hold-up timeï¼
PUP60/80 SERIES: 15 msec minimum at 110VAC
PUP130 SERIES: 10 msec minimum at 110VAC
Line regulationï¼
±0.5﹪maximum at full load
Inrush currentï¼
Withstand voltageï¼
15 amps @ 115VAC, or 30 amps @
230VAC, at 25â cold start
3000VAC from input to output
MTBFï¼
1500VAC from input to ground
500VAC from output to ground
PUP60/PUP80 300,000 hours
minimum, PUP130 400,000 hours
minimum at full load at 25â
ambient, calculated per
MIL-HDBK-217F, excluding DC
fan.
EMC performance (EN55024)
EN55022:
Class B conducted, class B radiated
FCC:
VCCI:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A
EN61000-3-3:
EN61000-4-2:
Line flicker
ESD, ± 8KV air and ± 4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ± 1KV
EN61000-4-5:
Surge, ± 1KV diff., ± 2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
EN61000-4-11:
Voltage dips, 30 ﹪ reduction for
500ms and >95﹪reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 â sales@trumpower.com â www.TRUMPower.com
|
▷ |