PUP30 Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 25- 30 WATT SWITCHING POWER SUPPLIES | |||
|
25- 30 WATT SWITCHING POWER SUPPLIES
DESCRIPTION
The PUP30 series of AC/DC switching power supplies are for
25 to 30 watts of continuous output power. They are enclosed
in a 94V-1 rated polyphenylene-oxide case with an IEC 320
inlet to mate with interchangeable cord for world-wide use. All
models meet CISPR 22 and FCC class B emission limits, and
comply with UL, CSA, IEC and CE requirements.
PUP30 SERIES
(LVD+EMC)
FEATURES
⧠15 standard desktop models
⧠Single, dual or triple outputs
⧠Optional output connectors
⧠Optional on/off switch
⧠100﹪ burn-in
⧠W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C
⧠Input surge current protection
⧠Overvoltage protection
⧠Overcurrent protection
Safety Standard Approvalsï¼
INPUT SPECIFICATIONS
Input voltageï¼
8 5 t o 2 6 4 VA C
Input frequencyï¼ 47 to 63 Hz
Input currentï¼
Leakage currentï¼
0 . 8 0 A ï¼ r m s ï¼ f o r 11 5 VA C
0 . 5 0 A ï¼ r m s ï¼ f o r 2 3 0 VA C
0 . 4 7 m A m a x . @ 11 5 VA C , 6 0 H z
0 . 8 5 m A m a x . @ 2 3 0 VA C , 5 0 H z
UL 60950-1
CSA C22.2 No. 60950-1
TÃV EN60950-1
OUTPUT SPECIFICATIONS
Output voltage/currentï¼
Output power rangeï¼
Ripple and noiseï¼
Overvoltage protectionï¼
Overcurrent protectionï¼
Temperature coefficientï¼
Transient responseï¼
See rating chart
30 watts maximum
1﹪peak to peak maximum
Provided on output #1 only; set
at 112 - 132 ﹪ of its nominal
output voltage
All outputs protected to short
circuit conditions
All outputs ±0.04 ﹪ / â
maximum
Maximum excursion of 4 ﹪ or
better on all models, recovering
to 1 ﹪ of final value within
500us after a 25﹪ step load
change
ENVIRONMENTAL SPECIFICATIONS
Operating temperatureï¼ 0â to +70â
Storage temperatureï¼ -40â to +85â
Relative humidityï¼
Deratingï¼
5﹪ to 95﹪ non-condensing
Derate from 100% at +50â linearly
to 50﹪at +70â
GENERAL SPECIFICATIONS
Switching frequencyï¼ 30KHz ±5KHz
Efficiencyï¼
Hold-up timeï¼
Line regulationï¼
70﹪minimum on single output models
with Vo ⥠12V, 65% minimum on the
others
10 msec minimum at 110VAC
±0.5﹪maximum at full load
Inrush currentï¼
15 amps @ 115VAC, or 30 amps @
230VAC, at 25â cold start
Withstand voltageï¼
3000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBFï¼
400,000 hours minimum at full load at
25âambient , calculated per
MIL-HDBK-217F
EMC performance (EN55024)
EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
Class B conducted, class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Harmonic distortion, Class A and D
Line flicker
ESD, ± 8KV air and ± 4KV contact
E N 6 1 0 0 0 - 4 - 3 : Radiated immunity, 3V/m
EN61000-4-4: Fast transient/burst, ± 1KV
EN61000-4-5: Surge, ± 1KV diff., ± 2KV com.
E N 6 1 0 0 0 - 4 - 6 : Conducted immunity, 3Vrms
E N 6 1 0 0 0 - 4 - 8 : Magnetic field immunity, 1A/m
E N 6 1 0 0 0 - 4 - 11 : Voltage dips, 30 ﹪ reduction for 500ms and
>95﹪reduction for 10ms