English
Language : 

3RE-12-96 Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 120 WATT POWER ADAPTERS
TRUMPower
DESCRIPTION
The 3RE series of AC/DC desktop power adapters
are capable of delivering 120 watts of continuous
output power. They are enclosed in a 94V-1 rated
polyphenylene-oxide case with an IEC 320/C6 inlet
to mate with interchangeable cord for world-wide
use. All models meet CISPR 22 and FCC class B
emission limits and comply with UL, CSA, IEC and
CE requirements.
F E AT U R E S
‧ High efficiency
‧ Low ripple & noise
‧ Overvoltage protection
‧ Short-circuit protection
‧ Overpower protection
‧ Over temperature protection
‧ 100% burn-in at full rated load
‧ Standby consumption less than 0.5W
‧ Compliant with CEC and Energy Star efficiency
level IV requirements
(For all models except 3RE-12-96)
‧ No load power consumption less than 0.5W
‧ Average active efficiency ≥85%
‧ Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Earth leakage current:
(Touch current)
90 to 260VAC
47 to 63Hz
2.0A (rms) for 115VAC
1.0A (rms) for 230VAC
150µA max. @ 115VAC, 60Hz
250µA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/current:
See rating chart
Total output power:
See rating chart
Ripple and noise:
350mV peak to peak
maximum
Overvoltage protection:
Set at 110-140% of its
nominal output voltage
Overcurrent protection:
All models protected to
short circuit conditions
Temperature coefficient:
All outputs ±0.04%/ºC
maximum
Transient response:
Maximum excursion of 4%
or better on all models,
recovering to 1% of final
value within 500µs after a
25% step load change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature:
Storage temperature:
Relative humidity:
0ºC to +40ºC
-20ºC to +80ºC
10% to 95% non-condensing
120 WATT POWER ADAPTERS
3RE SERIES
RoHS
Safety Standard Approvals:
UL 60950 3rd
CSA C22.2 No. 60950 3rd
Nemko EN60950:2000
GENERAL SPECIFICATIONS
Hold-up time:
15 msec minimum at 115VAC
Turn on delay time: 2 seconds maximum
Power factor:
0.98 typical at 115VAC
Efficiency:
Line regulation:
86% min.
(80% min. on 3RE-12-96, 3RE-15-105 )
±0.5% maximum at full load
Inrush current:
Withstand voltage:
60 amps @ 115VAC or 90 amps
@ 230VAC, at 25ºC cold start
3000VAC from input to output
1500VAC from input to ground
MTBF:
150,000 hours at full load at
25ºC ambient, calculated per
MIL-HDBK- 217F
EMC Performance (EN55024)
EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Harmonic distortion, Class A and D
Line flicker
ESD, ±8KV air and ±4KV contact
Radiated immunity, 3V/m
Fast transient/burst, ±1KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 1A/m
Voltage dips, 30% reduction for
500ms and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com