3G Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 180 WATT POWER ADAPTERS | |||
|
TRUMPower
DESCRIPTION
The 3G & 3RG series of AC/DC desktop power
adapters are capable of delivering 180 watts
continuous DC power. They are enclosed in a
94V-1 rated polyphenylene-oxide case with an IEC
320/C14 or IEC 320/C6 inlet to mate with
interchangeable cord for world-wide use. All
model meet CISPR 22 and FCC class B emission
limits, and comply with UL, CSA, IEC and CE
requirements.
FEATURES
⧠High Efficiency
⧠Low Ripple & Noise
⧠Overvoltage protection
⧠Short-circuit protection
⧠Overpower protection
⧠Over temperature protection
⧠100% burn-in at full rated load
⧠Compliant with CEC and Energy Star efficiency
level IV requirements
⧠No load power consumption less than 0.5W
⧠Average active efficiency â¥85%
⧠Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltageï¼
Input frequencyï¼
Input currentï¼
Earth leakage current:
( To u c h c u r r e n t )
90 to 264VAC
47 to 63 Hz
2.5Aï¼rmsï¼for 115VAC
1.25Aï¼rmsï¼for 230VAC
150µA max. @ 115VAC, 60Hz
250µA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/currentï¼
Total output powerï¼
Ripple and noiseï¼
See rating chart
See rating chart
380mV peak to peak maximum
O v e r v o l ta g e p r o t e c t i o n ï¼ Set at 110-140% of its nominal
output voltage
Overcurrent protectionï¼ All models protected to short
circuit conditions
Te m p e r a t u r e
All outputs ±0.04%/ºC maximum
coefficientï¼
Transient responseï¼
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
ENVIRONMENTAL SPECIFICATIONS
O p e r a t i n g t e m p e r a t u r e ï¼ 0ºC to +40ºC
S t o r a g e t e m p e r a t u r e ï¼ -20ºC to +80ºC
Relative humidityï¼
10% to 90% non-condensing
180 WATT POWER ADAPTERS
3G & 3RG SERIES
RoHS
Safety Standard Approvalsï¼
UL 60950
CSA C22.2 No. 60950
TÃV EN60950-1
GENERAL SPECIFICATIONS
Hold-up timeï¼
5 msec minimum at 100VAC or
240VAC
Turn on delay timeï¼ 3 sec maximum at 100VAC
Power Factorï¼
0.95 typical
Efficiencyï¼
87% minimum at 100VAC or 240VAC.
Line regulationï¼ Â±0.5% maximum at full load
Inrush currentï¼
120A max. @ 240VAC cold start
Withstand voltageï¼ 3000VAC from input to output
1500VAC from input to ground
MTBFï¼
100,000 hours at full load at
25ºC ambient, calculated per
MIL-HDBK- 217F
EMC Performance (EN55024)
EN55022:
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class D
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ±1KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
EN61000-4-11:
Voltage dips, 30% reduction for
500ms and >95% reduction for
10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 â Fax: 408-988-6622 â email: sales@trumpower.com â Website: www.TRUMPower.com
|
▷ |