English
Language : 

3F Datasheet, PDF (1/2 Pages) Tumbler Technologies + TRUMPower – 150 WATT POWER ADAPTERS
TRUMPower
DESCRIPTION
The 3F/3RF is a series of fan-less AC/DC switching
power adapters with 150 watts of continuous output
power. The units are enclosed in a 94V-1 rated
polyphenylene-oxide case with an IEC 320/C14 or
IEC320/C6 AC inlet to mate with interchangeable
cord for world-wide use. All model meet CISPR 22
and FCC class B emission limits, and comply with
UL, CSA, IEC and CE requirements.
FEATURES
‧ High efficiency
‧ Low ripple & noise
‧ Overvoltage protection
‧ Short-circuit protection
‧ Overpower protection
‧ Over temperature protection
‧ 100% burn-in at full rated load
‧ Standby consumption less than 1W
‧ Compliant with RoHS requirements
INPUT SPECIFICATIONS
Input voltage:
Input frequency:
Input current:
Earth leakage current:
90 to 264VAC
47 to 63 Hz
2.0A( rms) for 115VAC
1.0A( rms) for 230VAC
150µA max. @ 115VAC, 60Hz
250µA max. @ 230VAC, 50Hz
OUTPUT SPECIFICATIONS
Output voltage/current:
Total output power:
Ripple and noise:
See rating chart
See rating chart
380mV peak to peak maximum
Overvoltage protection:
Overcurrent protection:
Temperature coefficient:
Transient response:
Set at 110-140% of its nominal
output voltage
All models protected to short
circuit conditions
All outputs ±0.04%/ºC maximum
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: 0ºC to +40ºC
Storage temperature: -20ºC to +80ºC
Relative humidity:
10% to 90% non-condensing
150 WATT POWER ADAPTERS
3F/3RF SERIES
RoHS
Safety Standard Approvals:
UL 60950-1
CSA C22.2 No. 60950-1
Nemko EN60950: 2000
GENERAL SPECIFICATIONS
Hold-up time:
3 msec minimum at 100VAC
Turn on delay time: 5 seconds maximum at 100VAC
Power factor:
0.95 typical
Efficiency:
88% min.
Line regulation: ±0.5% maximum at full load
Inrush current: 60A @ 115VAC or 100A @ 230VAC,
at 25ºC cold star
Withstand voltage: 3000VAC from input to output
1500VAC from input to ground
MTBF:
150,000 hours at full load at 25ºC
ambient, calculated per
MIL-HDBK- 217F
EMC Performance (EN55024)
EN55022:
FCC:
VCCI:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
EN61000-4-11:
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Class B conducted, Class B radiated
Harmonic distortion, Class D
Line flicker
ESD, ±8KV air and ±4KV contact
Radiated immunity, 3V/m
Fast transient/burst, ±1KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 1A/m
Voltage dips, 30% reduction for
500ms and >95% reduction for
10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com