English
Language : 

856314_15 Datasheet, PDF (2/6 Pages) TriQuint Semiconductor – 140 MHz SAW Filter
Absolute Maximum Ratings
Parameter
Storage Temperature (1)
Operating Temperatures (2)
Rating
-40 to +85 oC
0 to +70 oC
856314
140 MHz SAW Filter
Notes:
1. Operation of this device outside the parameter ranges given
may cause permanent damage.
2. Specifications are not guaranteed over all operable conditions.
Electrical Specifications (1) (3)
Test conditions unless otherwise noted: (2) Temperature Range 0 to +70 oC
Parameter
Center Frequency
Maximum Insertion Loss
Lower 1.5 dB Bandedge (5)
Upper 1.5 dB Bandedge
Lower 3 dB Bandedge (5) 
Upper 3 dB Bandedge
Lower 40 dB Bandedge (5)
Upper 40 dB Bandedge
Amplitude Variation
Phase Linearity
Group Delay Variation
Relative Attenuation (5)
Temperature Coefficient
Source/Load Impedance (6)
Conditions
At center frequency
109 – 171 MHz
109 – 171 MHz
109 – 171 MHz
15 – 75 MHz
75 – 89 MHz
191 – 215 MHz
215 – 298 MHz
Single ended
Min
-
-
-
171
-
176
88--99
-
-
-
45
40
40
42
-
-
Typical (4)
140
21
103
177
102
178
97
186
0.7
4.0
30
50
43
44
46
-74
50
Max
-
22.5
109
-
104
-
-
191
1.5
10
100
-
-
-
-
-
-
Units
MHz
dB
MHz
MHz
MHz
dB p-p
deg p-p
ns p-p
dB
ppm/ oC
 Ω
Notes:
1.
2.
3.
4.
5.
6.
All specifications are based on the TriQuint schematic design shown on page 3.
In production, devices will be tested at room temperature to a guardbanded specification to ensure electrical compliance
over temperature.
Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing
tolerances.
Typical values are based on average measurements at room temperature.
Relative to insertion loss at center frequency.
This is the optimum impedance in order to achieve the performance shown.
Data Sheet: Rev. B 09-26-14
© 2014 TriQuint
- 2 of 6 -
Disclaimer: Subject to change without notice