PHYSICAL
Installation Form Factors Supported
with Included Accessories
Tower
Installation Form Factors Supported
with Optional Accessories
Wallmount (UPSWM - tower mounting kit)
Primary Form Factor
Tower
UPS Power Module Dimensions
(hwd, in.)
8.5 x 4.2 x 5.5
UPS Power Module Dimensions
(hwd, cm)
21.6 x 10.8 x 14
UPS Power Module Weight (lbs.)
10.9
UPS Power Module Weight (kg)
4.9
UPS Shipping Dimensions (hwd / in.) 11.5 x 4.8 x 8.5
UPS Shipping Dimensions (hwd /
cm)
29.2 x 12.1 x 21.6
Shipping Weight (lbs.)
12
Shipping Weight (kg)
5.4
UPS Housing Material
PVC
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Relative Humidity
AC Mode BTU / Hr. (Full Load)
Battery Mode BTU / Hr. (Full Load)
AC Mode Efficiency Rating (100%
Load)
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
0 to 95%, non-condensing
18.9
143.6
97%
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery
Power (Setpoint)
High Voltage Transfer to Battery
Power (Setpoint)
2-4 milliseconds
99V (adjustable to 83V via potentiometer)
176 (adjustable to 147 via potentiometer)
SPECIAL FEATURES
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS
CERTIFICATIONS