SU8000RT3UHW_15 Datasheet, PDF (1/6 Pages) Tripp Lite. All Rights Reserved – SmartOnline 200-240V 8kVA 7.2kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, 6U Rack/Tower, Bypass Switch, Hardwire
SmartOnline 200-240V 8kVA 7.2kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard, 6U Rack/Tower, Bypass Switch, Hardwire
MODEL NUMBER: SU8000RT3UHW
Highlights
8kVA / 8000VA / 7200W on-line
double-conversion UPS; 0.9
power factor
200/208/220/230/240V 50/60Hz
output, Economy mode option
6U Rack/Tower compatible;
Hot-swap power and battery
modules
USB, RS232 & EPO ports;
SNMP/WEB and contact-closure
card options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (3 wire); Hardwire
output (3 wire)
Description
Tripp Lite SU8000RT3UHW 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete
power protection for critical network applications. This system delivers online, double-conversion UPS protection
with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with
manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to
connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this
UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged
industrial locations.
Package Includes
SU8000RT3UPM 3U UPS power
module
BP240V10RT3U external battery
pack
SUPDMB710HW Detachable
PDU with manual bypass switch
Four post compatible rack rail kit
(2 sets)
Features
Tripp Lite SU8000RT3UHW 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 6U total
rack/tower configuration (3U UPS power module and 3U external battery pack)
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no
Tower stands for upright tower
configuration
PowerAlert software, complete
data cabling and user manual
interruption in output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input (3 wire) and hardwire output (3 wire) connections
Supports North American (L1,L2,G) 208/240v hardwire input / output, plus International 230/220/240v (L,N,PE) hardwire input / output
Optional SU6000XFMR2U transformer offers 120v output in North American 208/240V (L1,L2,G) input configurations
Maximum installed rack depth of only 32.5 in. / 82.6cm inches
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection
from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as
300V
1/6