English
Language : 

SU6000RT4UTFHW Datasheet, PDF (1/6 Pages) Tripp Lite. All Rights Reserved – SmartOnline 208/120V or 240/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run,SNMP, Webcard, 6U Rack/Tower, LCD, USB, DB9 Serial
SmartOnline 208/120V or 240/120V 6kVA 5.4kW
On-Line Double-Conversion UPS, Extended Run,
SNMP, Webcard, 6U Rack/Tower, LCD, USB, DB9
Serial
MODEL NUMBER: SU6000RT4UTFHW
Highlights
6kVA / 6000VA / 5400W on-line
double-conversion UPS; 0.9
power factor
208/120V or 240/120V 60Hz
output; Economy mode option
6U Rack/Tower installation;
Hot-swappable power and
battery modules
USB, RS232 & EPO ports;
SNMP/WEB and contact-closure
card options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (3 wire); NEMA
5-15R, 5-15/20R & Hardwire
outputs
Description
Tripp Lite SU6000RT4UTFHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers
complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower
compatible configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC
output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU
with manual bypass switch supports hot-swappable UPS power module replacement with no interruption to
connected equipment. 4U UPS power module and included 2U low-voltage transformer install in only 6 rack
spaces total (6U) with a maximum installed depth of only 21.8 in. / 55.3 cm. Maintains full-time sine wave output
within 2% of selectable 208/240V and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as
high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery
independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even
when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to
DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types.
Package Includes
SU6000RT4UHVPM
Hot-swappable UPS Power
Module
SUPDMB6KHW Detachable
PDU with Maintenance Bypass
Switch
SU6000XFMR2U Low voltage
transformer
PowerAlert Software CD
1 x 6-ft. USB Cable
1 x 6-ft. Serial Cable
4 Post Rackmount Hardware (2
sets)
Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise
suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional
SNMP/Web and contact-closure communications card accessories available. HID-compliant USB interface enables integration with built-in power management
and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed site power and UPS updates with support for
safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages include PowerAlert Local, PowerAlert Network
Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of application types. Supports Emergency Power Off
(EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS for a variety of control
options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. Hardwire
input. Hardwire UPS output, plus 1 L6-30R, 8 5-15/20R and 4 5-15R outlets. External battery packs are field replaceable and hot swappable. $250,000
1/6