English
Language : 

SU20KRTHWTFASSM Datasheet, PDF (1/6 Pages) Tripp Lite. All Rights Reserved – SmartOnline 240-120V 20kVA 18kW On-Line Double-Conversion UPS, Extended Run, SNMP,Webcard, USB, DB9 Serial, Hardwire
SmartOnline 240/120V 20kVA 18kW On-Line
Double-Conversion UPS, Extended Run, SNMP,
Webcard, USB, DB9 Serial, Hardwire
MODEL NUMBER: SU20KRTHWTFASSM
Highlights
20kVA / 20,000VA / 18,000W
on-line double-conversion UPS
240/120V 60Hz output; Economy
mode option
Hot-swap power and battery
modules, N+1 fault tolerance at
loads up to 50%
USB, RS232 & EPO ports;
pre-installed SNMPWEBCARD
network interfaces
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Pre-assembled 16U configuration
built into a 25U rack enclosure
Hardwire input and output
Description
Tripp Lite SU20KRTHWTFASSM 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers
complete power protection for critical server, network and telecommunications equipment in a 16U rack/tower
configuration pre-assembled into a Tripp Lite 25U rack enclosure. This system delivers complete N+1
redundancy when used at loads up to 50%, and non-redundant operation at loads between 50 and 100%.
Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault
conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major
UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and
simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers,
computer rooms, network closets and rugged industrial locations.
Package Includes
Two SU10000RT3UPM UPS
power modules
Two BP240V10RT3U battery
packs
One SU20KXFMRT4U 120V
transformer
SUPDMB20KHW parallel PDU
with Bypass switch
Pre-installed in a Tripp Lite 25U
Features
Tripp Lite SU20KRTHWTFASSM 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in a
16U total rack/tower configuration (max output de-rates to 18kVA / 16kW when operated at 208V nominal
rack enclosure
PowerAlert software and
complete cabling
input voltage)
Pre-built into a 25U SmartRack enclosure with 6U of open rack space able to accommodate two optional additional BP240V10RT3U external battery
packs
Offers enhanced fault-tolerance and reliability with N+1 configuration support and hot-swappable whole UPS replacement options
Unique configuration ties input, output and data connections of two standard 10kVA UPS systems via detachable parallel PDU to offer 20kVA
non-redundant operation and automatic N+1 redundancy at load levels of 50% and lower
Included Parallel PDU with manual bypass switching enables hot-swappable replacement of either power module at any supported load level, with no
interruption to connected equipment
Hardwire input and output connections
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
1/6