English
Language : 

SU16KRTG Datasheet, PDF (1/6 Pages) Tripp Lite. All Rights Reserved – SmartOnline 200-240V 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run,SNMP, Webcard, 12U Rack-Tower, USB, DB9 Serial,C19 Outlets
SmartOnline 200-240V 16kVA 14.4kW On-Line
Double-Conversion UPS, N+1, Extended Run,
SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial,
C19 Outlets
MODEL NUMBER: SU16KRTG
Description
Tripp Lite SU16KRTG 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete
power protection for critical server, network and telecommunications equipment in a 12U rack/tower
configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and
non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected
service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass
switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined
operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS
ideal for advanced networking applications in data centers, computer rooms, network closets and rugged
industrial locations.
Highlights
16kVA / 16,000VA / 14,400W
on-line double-conversion UPS,
0.9 power factor
200/208/220/230/240V 50/60Hz
output, 96% Efficient
Economy-mode option
Hot-swap power & battery
modules, N+1 fault tolerance at
loads up to 8kVA
USB, RS232, EPO ports, Support
for SNMP/WEB & other card
options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (3 wire), C19
outlets
Package Includes
Two SU8000RT3UPM UPS
power modules
Two BP240V10RT3U battery
packs
SUPDMB20KIEC Parallel PDU
with Bypass switch
4-post rackmount installation rails
PowerAlert software and cabling
Features
Tripp Lite SU16KRTG 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration
Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
Included Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load level
Hardwire input; 8 C19 outlets
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime with optional external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Battery independent restart
Highly efficient economy mode option
Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB interface module)
Applications utilizing the optional network communications card require two SNMPWEBCARD accessories (install one per included power module)
1/6