SU100KX2 Datasheet, PDF (1/5 Pages) Tripp Lite. All Rights Reserved – SmartOnline 100kVA Modular 3-Phase UPS System,On-line Double-Conversion International UPS
SmartOnline 100kVA Modular 3-Phase UPS System,
On-line Double-Conversion International UPS
Highlights
100kVA / 100,000VA / 80,000W
on-line double-conversion 3
MODEL NUMBER: SU100KX2
phase UPS
3 phase 220/380V, 230/400V,
240/415V 4-wire + ground wye
input & output
Scalable design grows as your
datacenter grows
Modular N+1 redundant
architecture helps assure 100%
availability
Parallel up to 4 UPS systems for
redundancy or increased capacity
IGBT & DSP technology produce
<4% input harmonic distiortion
(THDi)
Hot swappable power modules,
Description
Expandable runtime
Tripp Lite SU100KX2 100kVA SmartOnline Modular 3-Phase Intelligent, True On-Line Double-Conversion UPS
System provides 100% system availability with N+1 modular architecture and parallel capability. In N+1
configurations, SU100KX2 provides 5 self-contained, redundant 20kVA power modules that support
hot-swappable maintenance as connected equipment remains powered. One open slot for up to one additional
20kVA power module offers increased capacity upgrades to 120kVA. In parallel applications, configured and
installed by a Tripp Lite authorized technician, up to 4 SU100KX2 models can be connected to provide fail-safe
redundancy (two 100kVA models supporting up to 100kVA total load) or increased capacity (two 100kVA models
Package Includes
SU100KX2 UPS System
PowerAlert Software
Parallel communication cable
Instruction manual
Warranty information
supporting up to 200kVA total load). Large capacity 100,000VA / 80,000W UPS continually converts incoming
AC power into filtered DC and resynthesizes output into perfectly regulated continuous sine wave AC output with less than 3% THD. Zero transfer time assures
compatibility with all equipment types. High input power factor, advanced IGBT inverter and Digital Signal Processor (DSP) technology produce less than 4%
input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a
generator with a capacity equal to the equipment load (1:1 ratio). Up to 97% efficiency in optional economy mode reduces operating costs and BTU output.
Hardwire input and output connections support a variety of permanent or PDU power connections. Frequency is 50 or 60 Hz (auto-selectable). SU100KX2
power modules are housed in a single small-footprint tower compartment. Compatible battery pack models BP480V55, BP480V78, BP480V103 and
BP480V140 (sold separately) are housed in a separate stand-alone hardwired external battery compartment. Battery runtime can be extended with additional
stand-alone hardwired external battery modules. A manual bypass breaker and an automatic bypass function ensure 100% availability of connected
equipment by safely passing through AC power if the UPS requires maintenance.
Features
True On-Line Double-Conversion 100kVA / 100,000VA / 80kW / 80,000 watt SmartOnline Modular 3-Phase Intelligent UPS provides 100% system
availability
Scalable, modular N+1 configurations support hot-swap replacement of any of the six self-contained 20kVA power modules while connected equipment
remains powered
One open slot accommodates up to one additional 20kVA power module for increased capacity up to 120kVA
Parallel applications enable the connection of 2, 3 or 4 SU100KX2 models in parallel to enable advanced configurations for fail-safe redundancy,
increased capacity and combinations of the two (all parallel installations must be performed by a Tripp Lite authorized technician)