SRXCOOL33K Datasheet, PDF (1/3 Pages) Tripp Lite. All Rights Reserved – SmartRack 33,000 BTU 200-240V Energy-Saving, Row-Based Air Conditioning Unit with Hardwire Input
SmartRack 33,000 BTU 200-240V Energy-Saving,
Row-Based Air Conditioning Unit with Hardwire
Input
MODEL NUMBER: SRXCOOL33K
Description
The harder your data center, network closet or server room works, the more it heats up, leading to inefficient
operation, weakened performance and raised cooling costs. In fact, cooling can consume more than half of the
power used by a high-density installation—start saving power and money with Tripp Lite’s SRXCOOL33K today!
The SRXCOOL33K provides 33,000 BTU of efficient, reliable cooling in a 42U rack form factor. It features
cutting-edge components that limit inrush current and enable precision cooling adjustments to minimize power
consumption, maximize cooling and improve your application efficiency.
By delivering cold air high in the cold aisle, the SRXCOOL33K promotes temperature uniformity from 1U to 42U,
allowing your equipment to perform at its peak. Controlling the unit is simple with the intuitive LCD display, or
control it from anywhere in the world with the included Modbus card or an optional network interface (Tripp Lite
SNMPWEBCARD, sold separately). With hardwire input (user supplied IEC 309 32-amp set, optional) and
exhaust connection directly into the drop ceiling, you can install the unit with no electrician or contractor
necessary, saving on up-front installation costs. Maintenance is no-hassle due to the self-contained design,
which requires no water collection tank or extra plumbing, while RoHS compliance and eco-friendly R410a
refrigerant means you’ll never have to worry about meeting environmental standards.
Features
33,000 BTU (9.7kW) of cooling power with 1/3 less power consumption
Variable-speed, DC-inverter-driven compressor and microprocessor-controlled electronic expansion valve
(EEV) enable precision cooling adjustments--no more wasteful, noisy cycling between off and full blast
Soft-start feature limits inrush current to prevent introduction of line noise, voltage disruptions and potential
circuit overloads
Self-contained, zero-maintenance unit re-humidifies condensate and expels it through the exhaust air
stream--no floor drain, water collection tank, external condenser, refrigerant piping, duct work or plumbing
1/3
Highlights
33,000 BTU (9.7kW) of cooling
power with 1/3 less power
consumption
Variable-speed,
DC-inverter-driven compressor
and microprocessor-controlled
electronic expansion valve (EEV)
enable precision cooling
adjustments--no more wasteful,
noisy cycling between off and full
blast
Soft-start feature limits inrush
current to prevent introduction of
line noise, voltage disruptions
and potential circuit overloads
Self-contained,
zero-maintenance unit
re-humidifies condensate and
expels it through the exhaust air
stream--no floor drain, water
collection tank, external
condenser, refrigerant piping,
duct work or plumbing required
Hardwire Input (User-supplied
IEC 309 32-amp set, optional) -
no electrician needed
200-240V AC Input, 50/60 Hz
frequency compatibility
1 year limited warranty
Applications
Supplemental cooling of data center
equipment in confined areas where the
facility HVAC is inadequate or doesn't
reach.
Package Includes
SRXCOOL33K Air Conditioning
Unit
Flexible Air Ducts
Unpacking Guide, Installation
Manual and Owner’s Manual
Unloading Ramps
Hot Exhaust Removal Tube